background image

YCO-1047-03-13

PPC-200(W)

 

Operation Manual

VII  User Parameter

 

Key  

Std 

Function 

Description

 

Word Value

 

01 

015 

Auto-off timer 

000  Disables auto-off.

 

 

 

 

001~240  Number of minutes unused to activate auto-off.

 

02 

000 

Display hold timer 

000  No display hold for changes less than four divisions.

 

 

 

 

001~030  Display hold duration, in seconds, for changes less

 

 

 

 

 

than four divisions.

 

 

 

 

031  No display hold.

 

03 

001 

Communication 

000  No serial interface.

 

 

 

 

001  Specified commands acceptable.

 

 

 

 

002  Sends zero detection.

 

 

 

 

003  Sends motion detection.

 

 

 

 

004  Sends continuously.

 

04 

000 

Communication data 

000  Net weight (1 batch)

 

 

 

 

001  Net weight, tare weight, gross weight (1 batch)

 

 

 

 

002  Net weight, tare weight, gross weight (3 batches)

 

 

 

 

003  Display content (1 batch)

 

 

 

 

004  Serial printer format (1 batch)

 

05 

000 

Communication speed 

000  9600 bps

 

 

 

 

001  600 bps

 

 

 

 

002  1200 bps

 

 

 

 

003  2400 bps

 

 

 

 

004  4800 bps

 

 

 

 

005  9600 bps

 

 

 

 

006  19200 bps

 

 

 

 

007  38400 bps

 

06 

000 

Character length 

000  8 bits

 

 

 

 

001  7 bits

 

07 

002 

Parity  

000  Non

 

 

 

 

001 Odd

 

 

 

 

002 Even

 

08 

001 

Stop bit length 

000  1 bit

 

 

 

 

001  2 bits 

 

09 

001 

Default mode 

000  kg

 

 

 

 

001 lb/oz

NOTICE

The RS-232 serial interface option is only available and legal-for-trade on CPU versions 4.02 and 

above.  See section 4 (Changing the Scale Setup - Test Mode) of the PPC-200(W) Technical Manual 

for instructions on how to enter test mode and view the CPU version.  See the PPC RS232 Operation 

Manual for more information on using the RS-232 serial interface option.

11

Содержание PPC-200

Страница 1: ...ORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827...

Страница 2: ...he weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the plat form or drop...

Страница 3: ...e 2 C Turning the Scale On and Off 2 D Checking the Battery Level 2 E Zero the Display 2 F Switching Between LB and KG 2 G Setting the Over Under Indicator 3 H Weighing 4 1 Using the Over Under Indica...

Страница 4: ...legal for trade operation 14 Battery Cover Tighten securely to maintain washdown seal 15 Outlet of AC adaptor cable Use of an AC adapter voids washdown seal 16 Levelling Legs Rotate to level the scal...

Страница 5: ...securely into the jack Do not washdown the scale if an AC adaptor is in use or if the washdown plug has been removed from the AC jack III B Leveling the Scale Place the scale on a flat and level surfa...

Страница 6: ...indicated as under 6 Press and hold the key and push the key Yellow Cor ners This saves the lower limit and moves to the upper limit 7 Press the key to select the digit you want to change 8 Press the...

Страница 7: ...ess than the under setpoint the large under arrow will appear 3 If the item weighs from the lower setpoint to the upper setpoint inclusive the accept bullseye will appear 4 If the item weighs more tha...

Страница 8: ...ight of the item s and the container Press the key again to return to the net weight 5 To return to gross weighing mode remove all items from the scale platform and press the key III H 4 Batching 1 Be...

Страница 9: ...meter mode This will also activate the CAL annunciator indicating that the scale is not properly configured for legal for trade operation For more information on setting system parameters and entering...

Страница 10: ...nual 7 IV Entering User Parameter Mode 3 To change a parameter value use the keys as follows increase value by one increase value by ten decrease value by one decrease value by ten 4 Press to save cha...

Страница 11: ...t and the indicator will move to the under range 2 Use the and keys to align the indicator with the low end of the under range 3 Press the key The indicator will move to the over range 4 Use the and k...

Страница 12: ...ntil the entire number is set 5 Press the key again to save the displayed under setpoint and to display the current over setpoint 6 Press the key to select the digit you want to change 7 Press the or...

Страница 13: ...layed It is usually displayed when the plat form is removed or has something wedged under it 4 Initial error on startup When the initial weight is heavier than the permissible zeroing range and the ke...

Страница 14: ...weight gross weight 1 batch 002 Net weight tare weight gross weight 3 batches 003 Display content 1 batch 004 Serial printer format 1 batch 05 000 Communication speed 000 9600 bps 001 600 bps 002 1200...

Отзывы: