background image

INTRODUCTION 

Thank you for purchasing a Yamato Portion Scale. Please read this 

instruction manual carefully before use. Keep these instructions 

handy for future reference. 

 

SAFETY INSTRUCTION 

Before  putting  the  device  into  use,  please  read  with  care  the 

information  given  in  the  Operating  Instructions.  They  contain 

important instructions for installation, proper use and maintenance of the 

device. 

The manufacturer shall not be liable for damages arising out of failure to 

heed the following instructions:   

 

When using electrical components under increased safety requirements, 

always comply with the appropriate regulations.   

 

Improper installation will render the warranty null and void. 

 

Ensure the voltage marked on the power supply unit matches your mains 

power supply. 

 

This device is designed for use indoors.   

 

Observe the permissible ambient temperatures for use 

 

The device meets the requirements for electromagnetic compatibility. Do 

not exceed the maximum values specified in the applicable standards. 

 

These batteries should be kept away from small children.    If swallowed, 

promptly seek medical assistance. 

 

Expected Service Life: 5 years 

If you have any problem, contact your local service partner. 

 

 

 
 

 

CLEANING 

 

We  would  recommend  using  alcohol  based  wipes  or  similar  when 

cleaning the scales. 

 

Please do not use large amounts of water when cleaning the scales as 

this will cause damage to the scales electronics, you should also refrain 

from using corrosive liquids or high pressure washers. 

 

Always  disconnect  the  scales  from  the  mains  power  supply  before 

cleaning. 

 

MAINTENANCE 

 

The  scale  does  not  require  any  routine  maintenance.  However,  we 

recommend  checking  the  scale’s  accuracy  at  regular  intervals.  The 

regularity of these checks is dependent on the level of use and the state 

of the scale. If any inaccuracies occur, please contact your local dealer or   

service partner 

 

DISPOSING OF THE SCALE 

 

This product is not to be treated as regular household waste, but should 

be handed in to an electrical/electronic equipment recycling centre. 

 

You  can  obtain  further  details  from  your  local  council,  your  municipal 

waste disposal company or the firm which you purchased the product 

 

 

 

 

 

 

Содержание AW-WSM-5KG

Страница 1: ...DUCTION 2 SAFETY INSTRUCTION 2 CLEANING 3 MAINTENANCE 3 DISPOSING OF THE SCALE 3 Explanation of the graphic symbols 4 TO Ready Scale for Use 5 POWER SUPPLY LOW BATTERY 5 INSTALLING THE BATTERY 6 SPECIFICATIONS 7 PANEL AND LCD DISPALY 8 LCD DISPLAY 8 KEY FUNCTION DESCRIPTION 9 CALIBRATION PROCEDURE 10 INSTRUCTION AUTO SHUT OFF FUNCTION 11 ERROR MESSAGE 12 ROHS COMPLIANCE 15 ...

Страница 2: ...plicable standards These batteries should be kept away from small children If swallowed promptly seek medical assistance Expected Service Life 5 years If you have any problem contact your local service partner 3 CLEANING We would recommend using alcohol based wipes or similar when cleaning the scales Please do not use large amounts of water when cleaning the scales as this will cause damage to the...

Страница 3: ... manual before setup and commissioning even if you are already familiar with Yamato scales 5 TO Ready Scale for Use 1 Remove the scale from its box along with any protective film from the platform cover 2 Place the scale on a hard flat surface Uneven surfaces will affect accuracy If using the adapter make sure the scale is not resting on the cord otherwise it may be unstable POWER SUPPLY LOW BATTE...

Страница 4: ...attery 4 Reinstall the battery housing cover You can also use the adaptor standard as power supply Battery housing cover 7 SPECIFICATIONS MODEL AW WSM 5KG Capacity Division 5000g x 1g Units of Measure kg lb Function keys ON OFF TARE ZERO UNIT Stabilisation Time 1 2 seconds Operating Temp and humidity 0 C 40 C 35 90 RH Transport and storage temperature and humidity 20 C 60 C 25 95 RH 9 volt battery...

Страница 5: ... a container from the reading of the instrument thus giving the true weight of the product being tested 1 Turn on the scale by pressing the ON OFF key 2 When 0 is displayed place the object to be tared on the scale platform 3 Press the TARE ZERO key after the weight stabilizes and stable annunciator appears on the display 4 The display will return to 0 5 Place the item to be weighed without removi...

Страница 6: ... calibration weight 5000g carefully in the centre of the scale plate and the display will show SPAN Count value 4000 80000 Press the ZERO TARE key The adjustment process is started 7 When the adjustment is finished successfully the scale is automatically switched over to the weighing mode again and the calibration weight value will be displayed 8 Remove the calibration weight Re power on the instr...

Страница 7: ... loading and try again Counting error too high Indicates that the signal from the load cells is too high This error is normally caused by a serious fault on the scales i e a faulty load cell or wiring Please contact the local Service Representative Counting error too low Indicates that the signal from the load cells is too low This error is normally caused by a serious fault on the scales such as ...

Страница 8: ...her temperatures required by lead free soldering The restricted substances and maximum allowed concentrations in the homogenous material are by weight Substance Concentration Lead 0 1 Mercury 0 1 PBB Polybrominated Biphenyls 0 1 PBDE Polybrominated Diphenyl Ethers 0 1 Hexavalant Chromium 0 1 Cadmium 0 01 YAMATO CORPORATION 1775 S Murray Bivd Colorado Springs Co 80916 USA Tel 719 591 1500 Fax 719 5...

Отзывы: