4.
Take special care to keep the ventilation inlets /outlets free from obstruction.
Cleaning with a soft brush followed by a compressed air jet will usually be sufficient
to ensure acceptable internal cleanliness.
5.
Wear eye protection when carrying out cleaning.
Repairs
1.
Only an authorized service centre should repair the generator.
Troubleshooting
Trouble
Possible cause
Suggested remedy
Engine will not start
1. low on fuel/oil content
1. add fuel/oil mix
2. ignition switch in ‘’off’’
position
2. turn to ‘’on’’ position
3. faulty spark plug
3. replace spark plug
4. choke in wrong position
4. adjust choke accordingly
5. unit loaded during start-up 5. remove load from unit
6. spark plug wire loose
6. Attach wire to spark plug.
7. unit may be flooded
7. Leave the generator rest
for 5-10 minutes and then try
again, following the
instructions when doing so.
Alternatively if the choke
lever is in full choke position
(start), switch the choke to
the run position and try to
re-start.
8. old fuel
8. remove the existing fuel
and replace with new
AC power supply-
No electrical output
1. faulty receptacle
1. have service centre
replace receptacle
2 .faulty power cord
2. Replace cord.
DC power supply-no
electrical output
1. circuit breaker kicked out
(DC only)
1. Yes-Depress the reset
button, to rest the circuit
breaker.
Repeated circuit
breaker tripping
1. overload
1. reduce load
2. faulty cords or equipment
2. Check for damaged,
bare, or frayed wires on
equipment. Replace.
3. Incorrect cables used.
3. Check to make sure you
are using the DC Cables
could result in the crossing
over of polarity,
4. mixed polarity
4. Check to make sure that
the DC cables are
connected to the correct
battery polarity terminals.