background image

To AC outlet

This unit

OUTPUT

INPUT1

TO SPEAKERS

FROM AMPLIFIER

INPUT2

PHASE

ON OFF

AUTO
POWER

NOM

REV

OUTPUT

INPUT2

PHASE

TO SPEAKERS

INPUT1

FROM AMPLIFIER

ON OFF

AUTO

POWER

NOM

REV

Right speaker

Left speaker

Amplifier

To AC outlet

This unit

Right speaker

Left speaker

Amplifier

OUTPUT

INPUT1

TO SPEAKERS

FROM AMPLIFIER

INPUT2

PHASE

ON OFF

AUTO
POWER

NOM

REV

To AC outlet

This unit

OUTPUT

INPUT1

TO SPEAKERS

FROM AMPLIFIER

INPUT2

PHASE

ON OFF

AUTO
POWER

NOM

REV

OUTPUT

INPUT2

PHASE

TO SPEAKERS

INPUT1

FROM AMPLIFIER

ON OFF

AUTO

POWER

NOM

REV

OUTPUT

INPUT2

PHASE

TO SPEAKERS

INPUT1

FROM AMPLIFIER

ON OFF

AUTO

POWER

NOM

REV

5

CONNECTIONS

Before attempting to make any connections to or from this unit, be sure to first switch OFF the power to this unit and to any other
components to which connections are being made.

When making connections between this unit and other components, be sure all connections are made correctly and consistently,
that is to say (left) to L(right) to R, “+” to “+” and “” to “”.

This unit can be connected to either the speaker terminals or the line output (pin jack) terminals of the amplifier. Choose one of
the ways shown below according to your audio system.  Also, refer to the owner’s manual for each component to be connected
to this unit.

CONNECTING TO SPEAKER TERMINALS OF THE AMPLIFIER

Disconnect your main speakers from the amplifier and connect them to this unit.

If using one unit

If using two units

Содержание YST-SW150/80

Страница 1: ...closure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert you to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance Explanation of Graphical Symbols CAUTION Active Servo Processing Subwoofer System Built in 100W Power Amp...

Страница 2: ...osed to rain or D The unit does not appear to operate normally or exhibits a marked change in performance or E The unit has been dropped or the cabinet damaged 16 Servicing The user should not attempt to service the unit beyond those means described in the operating instructions All other servicing should be referred to qualified service personnel 17 Power Lines An outdoor antenna should be locate...

Страница 3: ...ions Part 15 for Class B digital devices Compliance with these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with other electronic devices This equipment generates uses radio frequencies and if not installed and used according to the instructions found in the users manual may cause interferen...

Страница 4: ...h saves you the trouble of pressing the POWER switch when turning the power on and off If using one subwoofer it is recommended to place it on the outside of either the right or the left main speaker See fig If using two subwoofers it is recommended to place them on the outside of each main speaker See fig The placement shown in fig is also possible however if the subwoofer system is placed direct...

Страница 5: ...TO POWER NOM REV 5 CONNECTIONS Before attempting to make any connections to or from this unit be sure to first switch OFF the power to this unit and to any other components to which connections are being made When making connections between this unit and other components be sure all connections are made correctly and consistently that is to say L left to L R right to R to and to This unit can be c...

Страница 6: ...mage this unit your amplifier and or speakers How to Connect Red positive Black negative Unscrew the knob Insert the bare wire Remove approx 5mm 1 4 insulation from the speaker wires Tighten the knob and secure the wire Banana Plug connections are also possible except for U K and Europe models Simply insert the Banana Plug connector into the corresponding terminal Connecting to this unit s OUTPUT ...

Страница 7: ...other speakers should not be connected to the OUTPUT terminals on the rear panel of this unit If connected they will not produce sound When connecting to a monaural line output terminal of the amplifier connect to either the left or right INPUT 2 terminal PRE OUT Amplifier Pin plug cords Right speaker Left speaker To AC outlet This unit OUTPUT INPUT1 TO SPEAKERS FROM AMPLIFIER INPUT2 PHASE ON OFF ...

Страница 8: ...he source being played is stopped or the input signal is cut off for several minutes This function will operate responding to a certain level of input signal Increase the output level on the input source if the automatic power ON function will not operate or decrease the level if the automatic power OFF function will not operate There may be a case that the power turns on unexpectedly by sensing n...

Страница 9: ...l For adjusting the VOLUME control the HIGH CUT control and the PHASE switch refer to FREQUENCY CHARACTERISTICS on the next page For effective adjustment of the HIGH CUT control First set this control at about the main speakers rated minimum reproduceable frequency Then turn up the VOLUME control gradually and set it at a level where you can obtain a little more bass effect than when this unit is ...

Страница 10: ...HASE Set to the reverse REV position HIGH CUT VOLUME 140 Hz 0 10 40 Hz VOLUME 0 10 HIGH CUT 150 Hz 50 Hz 20 50 100 200 500Hz 40 50 60 70 80 90 dB HIGH CUT 50 Hz HIGH CUT 150 Hz HIGH CUT 100 Hz 20 50 100 200 500Hz 40 50 60 70 80 90 dB HIGH CUT 90 Hz HIGH CUT 140 Hz HIGH CUT 40 Hz 20 50 100 200 500Hz 40 50 60 70 80 90 dB YST SW80 20 50 100 200 500Hz 40 50 60 70 80 90 dB YST SW150 20 50 100 200 500Hz...

Страница 11: ...solved through the employment of a design in which the amplifier functions to supply special signals If the electrical resistance of the voice coil could be reduced to zero the movement of the speaker unit would become linear with respect to signal voltage and to accomplish this a special negative impedance output drive amplifier for subtracting output impedance of the amplifier is used By employi...

Страница 12: ... and Canada models AC 120V 60 Hz Australia model AC 240V 50 Hz U K and Europe models AC 230V 50 Hz General model AC 110 120 220 240V 50 60 Hz Power Consumption 130W Dimensions W x H x D 252 mm x 620 mm x 418 mm 9 15 16 x 24 7 16 x 16 7 16 Weight 18 kg 39 lbs 10 oz Please note that all specifications are subject to change without notice YST SW150 Type Active Servo Processing Subwoofer System Speake...