INSP
ADJ
10
2. Replace:
• Blown fuse
Replacing steps:
• Set the main switch to “OFF”.
• Install a new fuse of the correct amperage.
• Set the main switch to “ON” and verify if the
electrical circuit is operational.
• If the fuse immediately blows again, check
the electrical circuit.
WARNING
Never use a fuse with an amperage other
than that specified. Improvising or using a
fuse with the wrong amperage rating may
cause extensive damage to the electrical
system, cause the lighting, ignition, grip
warmer, signal and meter systems to mal-
function and could possibly cause a fire.
Item
Amperage
Q’ty
Main fuse
30 A
1
Headlight fuse
20 A
1
Signal fuse
10 A
1
Ignition fuse
20 A
1
Carburetor
heater fuse
20 A
1
DC terminal
fuse
3 A
1
Reserve fuse
20 A
1
10 A
1
3 A
1
Reserve fuse
30 A
1
FUSE INSPECTION