20
Changing the driver setting (MIDI
Patch Screen)
You can change the assignment of I/O ports on the UX96 and port numbers
selected from your computer.
Sequence software transmits and receives MIDI signals to and from the UX96 via
the driver (page 10). The UX96 features MIDI IN/OUT terminals and a TO TG/
INST terminal. Select the I/O ports on the UX96 from your computer (sequence
software). You specify the I/O ports of the UX96 using the computer’s sequence
software. Changing the driver setting enables you to change I/O assignments
without re-patching cables.
For example, you can transmit an identical MIDI signal to multiple ports, or
transmit layered MIDI signals from multiple ports to a single port. Also, you can
directly route MIDI signals from MIDI IN to MIDI OUT.
The following table shows the assignment of the port numbers and I/O ports.
With the default settings, the port number matches the computer’s port number.
If a tone generator connected to the TO TG/INST terminal does not support multiport
specifications, the selection of ports B–E will be ignored.
port number
MIDI output port
MIDI input port
Port 1
MIDI OUT
MIDI IN
Port 2
TO TG/INST -A
TO TG/INST
Port 3
TO TG/INST -B
—
Port 4
TO TG/INST -C
—
Port 5
TO TG/INST -D
—
Port 6
TO TG/INST -E
—
NOTE