8-6
●
Before charging:
only add distilled water if
fluid is below the top of the plates, and then
add just enough to cover plates.
●
After charging:
check that the fluid level is
approximately 6.4 mm (0.25 in) to 12.7 mm
(0.5 in) above the plates and 6.4 mm
(0.25 in) to 9.7 mm (0.38 in) below the level
indicator. If the fluid level is low, carefully
add distilled water. Adding distilled water
after charging helps prevent boil over.
1. Battery cap
2. Plates
3. Maximum fluid level
4. Minimum fluid level
CAUTION:
Normal tap water contains minerals which
are harmful to a battery; therefore, refill
only with distilled water.
3. Using a hydrometer, check the specific
gravity of the battery fluid in each cell
against the readings on the following
chart. Consult a Yamaha dealer if any
low readings are found, or if readings
vary more than one point between cells.