background image

Key

 

sensor

 

unit

 

adjustment

In

 

the

 

case

 

of

 

YC1,

 

YF101,

 

U1,

 

YUS1,

 

U3,

 

YUS3,

 

YUS5

 

and

 

SU7

 

pianos.

[Standard]

[Procedure]

 

KS

 

spacer

In

 

the

 

case

 

of

 

P116,

 

P121

 

and

 

M

 

type

 

pianos.

[Standard]

[Procedure]

Pedal

 

sensor

 

unit

 

adjustment

[Damper

 

pedal

 

detection

 

position

 

adjustment]

[Soft

 

peal

 

sensor

 

detection

 

position

 

adjustment]

In

 

the

 

case

 

of

 

Sostenuto

 

Model

 

piano.

[Sosutenuto

 

peal

 

sensor

 

detection

 

position

 

adjustment]

Description

Part

 

No.

Remarks

KS

 

spacer

ZE83100S

Black

   

t=0.5mm

Fig.9

Upright

 

Piano

KS

 

spacer

Fig.10

KS

 

block

a

KS

 

bracket

 

screw

KS

 

block

 

binder

Fig.11

Adjust

 

the

 

gap

 

between

 

the

 

bottom

 

surface

 

of

 

a

 

black

 

key

 

located

 

near

 

the

 

sensor

 

bracket

 

and

 

the

 

upper

 

surface

 

of

 

the

 

key

 

sensor

 

unit

 

to

 

3.0mm

 

to

 

5.0mm

 

when

 

depressing

 

the

 

black

 

key

 

to

 

the

 

lowest

 

point,

 

and

 

the

 

gap

 

between

 

the

 

keyboard

 

and

 

Key

 

sensor

 

rail

 

so

 

that

 

it

 

is

 

parallel,

 

also

 

when

 

depressing

 

the

 

black

 

key

 

to

 

the

 

lowest

 

point.

  

(Fig.9.)

Adjust

 

the

 

number

 

of

 

KS

 

spacers

 

to

 

make

 

a

 

gap

 

of

 

appropriate

 

size.

 

When

 

you

 

remove

 

or

 

add

 

a

 

KS

 

spacer,

 

removing

 

the

 

Key

 

sensor

 

bracket

 

from

 

the

 

KS

 

block

 

is

 

required.
Adjustment

 

spots

 

:

 

Sensor

 

brackets:

 

4

Adjustment

 

hint:

 

2

 

each

  

(Fig.10.11)

To

 

narrow

 

a

 

gap

 

:

 

Add

 

KS

 

spacer(s)

To

 

increase

 

a

 

gap

 

:

 

Remove

 

KS

 

spacer(s)

Damper

 

pedal

 

detection

 

position

 

adjustment

 

shall

 

be

 

done

 

with

 

registering

 

Half

 

point

 

position

 

in

 

the

 

Damper

 

Pedal

 

Calibration

 

mode.

 

Please

 

refer

 

to

 

5.

 

Calibration

 

Mode

 

(Page

 

12).

Shift

 

/

 

Sosutenuto

 

pedal

 

sensor

 

detection

 

position

 

adjustment

 

shall

 

be

 

done

 

with

 

the

 

test

 

mode

 

buzzer

 

sounding

 

positions.

  

Please

 

refer

 

to

 

6.

 

Test

 

Mode

 

(Page

 

15).

Adjust

 

the

 

gap

 

between

 

the

 

bottom

 

surface

 

of

 

a

 

black

 

key

 

located

 

near

 

the

 

sensor

 

bracket

 

and

 

the

 

upper

 

surface

 

of

 

the

 

key

 

sensor

 

unit

 

to

 

3.0mm

 

to

 

5.0mm

 

when

 

depressing

 

the

 

black

 

key

 

to

 

the

 

lowest

 

point,

 

and

 

the

 

gap

 

between

 

the

 

keyboard

 

and

 

Key

 

sensor

 

rail

 

so

 

that

 

it

 

is

 

parallel,

 

also

 

when

 

depressing

 

the

 

black

 

key

 

to

 

the

 

lowest

 

point.

 

(Fig.12)

Adjust

 

from

 

the

 

upside

 

of

 

the

 

keyboard

 

with

 

2

 

adjustment

 

screws

 

to

 

make

 

a

 

gap

 

of

 

appropriate

 

size.

Adjustment

 

spots

 

:

 

Sensor

 

brackets:

 

4

Adjustment

 

screws:

 

2

 

each

  

(Fig.12)

Fig.12

Adjustment

 

screws

a

Sosutenuto

 

pedal

 

sensor

 

detection

 

position

 

adjustment

 

shall

 

be

 

done

 

with

 

the

 

test

 

mode

 

buzzer

 

sounding

 

positions.

  

Please

 

refer

 

to

 

6.

 

Test

 

Mode

 

(Page

 

15).

‐ 11 ‐

Содержание Silent Piano GPS-SH Series

Страница 1: ...Grand Piano Upright Piano Feb 2013 Ver 1 0 SH Series MAINTENANCE HANDBOOK MHB32 ...

Страница 2: ......

Страница 3: ...in WAV format can be played on a PC as well While the Grand Silent Piano requires lever operation for switching to Silent mode SH type Silent Piano does it all via motor activation with a single press of a button The headphones that come exclusively with SH type pianos are designed in a way that minimizes the strain on users after long hours of playing These newly employed headphones contribute to...

Страница 4: ...per Pedal 5 GM Unit AC Adaptor PJP PS04 4 3 2 1 5 4 3 2 1 5 1 Switch Box 2 Soft Pedal 3 Silent Pedal Sostenuto Pedal Sostenuto model only 4 Damper Pedal 5 DC IN Unit Soundboard Side 6 Silent Lever Sostenuto model only AC Adaptor PA 150A AC Adaptor PJP PS04 U model only Grand Piano Upright Piano 6 4 ...

Страница 5: ...AUSE Button 6 NO YES Button 7 FUNC Button 8 Function Indicator 9 Display 10 USB Terminal 11 PHONES Jacks Stereo Mini 12 VOLUME Control 13 DC IN 12V Connector 14 MIDI IN MIDI OUT Connectors 15 AUX IN AUX OUT Jacks Stereo Mini 1 OUTPUT L L R R Jacks 2 OUTPUT VOL Control 10 11 12 14 15 13 1 2 3 4 5 6 7 8 9 1 2 Upright Piano Grand Piano Grand Piano 5 ...

Страница 6: ...s as shown in a picture Remove white square connector Loosen cable ties to release sensor cable from Hammer rail Headphone hanger A B Grand Piano Upright Piano When an Headphone hanger is attached to the bottom of the Switch Box to remove the Headphone hanger loosen the screws as shown in the figure then slide the Headphone hanger towards you When pulling an action make sure that the Silent mechan...

Страница 7: ... vertical to the hammer shank when the silent mechanism is active Fig 2 B A Grand Piano Hammer shank stopping position to 5mm 6mm from the strings Adjustment of action in the Silent mode is done with the Silent mechanism engaged Switching of silent normal play is done with the POWER or QUIET button on the front panel for Grand Piano with the Silent Pedal Center for Upright Piano Adjust and set the...

Страница 8: ... the hammer drop on samples to the original position Silent let off Shank stopping position 1mm to 2mm a b Regulating rod drive lever adjustment screw Regulating rod adjustment screw Small jack s knob a and Regulating rod b respectively contact in the center position when Silent mechanism is engaged Fig 3 Small jack s knob a does not contact the Regulating rod when Silent mechanism is disengaged A...

Страница 9: ...e silent mechanism is disengaged hammer shanks do not contact the hammer shank stopper when depressing keys Rotate turn buckle counterclockwise to make Shank stop position narrower Rotate turn buckle clockwise to make Shank stop position wider In case the Shank stop position differs between sections loosen adjustment screws and adjust the position of the rails of each section on the shank stopper ...

Страница 10: ...r the sensor bracket and the upper surface of the key sensor unit to 3 0mm to 5 0mm when depressing the black key to the lowest point and the gap between the keyboard and Key sensor rail so that it is parallel also when depressing the black key to the lowest point Fig 6 Adjust from the bottom of the keyboard with 2 adjustment screws to make a gap of appropriate size Adjustment spots Sensor bracket...

Страница 11: ... sensor bracket from the KS block is required Adjustment spots Sensor brackets 4 Adjustment hint 2 each Fig 10 11 To narrow a gap Add KS spacer s To increase a gap Remove KS spacer s Damper pedal detection position adjustment shall be done with registering Half point position in the Damper Pedal Calibration mode Please refer to 5 Calibration Mode Page 12 Shift Sosutenuto pedal sensor detection pos...

Страница 12: ...on Depress the damper pedal or push the PLAY button once to the register rest value then proceed to step 4 Pressing the same key more than once has no effect on measurement 3 sec intermittent tone Confirm all keys are in the rest position Depress the damper pedal or push the PLAY button once to register the rest value then proceed to step 3 If the key is in the wrong position correct to the rest p...

Страница 13: ... Soft pedal or press the STOP button once to go back to step 2 2 Key Complete to be measured Check Keyboard No of the Key to be measured on the display Depress the damper pedal or push the PLAY button once to to determine the key to be measured In case of changing the key selection press another measuring key 1 Aging Wait till aging is done AGI is indicated and DP blinks on the display while aging...

Страница 14: ... the half point position 7 Finish Flash ROM writing is indicated on the display while the Flash ROM is writing PAS indicates when writing is finished Status Damper Pedal Sensor Measurement Pedal at the rest position Pedal not depressed No tone Buzzer sound Display Refer to Start up 3 sec intermittent tone nG and Keyboard No are indicated on the display one after the other if Flash ROM writing has ...

Страница 15: ...f or select t49 to terminate the test mode Display Test No Testing item t02 t04 t07 Mode Method Operation Test mode Panel button Keyboards t06 t47 t05 t49 Upright Piano Grand Piano Execute the selected testing item Complete test YES PLAY PLAY YES YES YES NO NO NO PLAY Test mode is a program for inspecting the operation of the electric system The test mode is equipped with test items that check the...

Страница 16: ...ent Screw Damper Pedal Sensor Adjustment Sostenuto Pedal Sensor Adjustment Screw Soft Pedal Sensor Adjustment Screw Sensor Adjustment Screw Pedal or Pedal lever Grand Piano Upright Piano Upright Piano Sostenuto Model Sostenuto Pedal Sensor Adjustment Screw 16 ...

Страница 17: ...tion Press the YES NO button to select t04 then press the PLAY button once to execute the test Status Operation Buzzer sound Complete Push the PLAY button once to terminate the sensor testing item In between Hammer rest position to M1 detection position No buzzer sound Execute Hammer sensor test M2 detection position Shank stop position 0 5mm to 2 5mm Continuous tone Confirmation Press the QUIET b...

Страница 18: ...terminate the sensor testing item Execute Soft pedal sensor test Press the YES NO button to select t05 then press the PLAY button once to execute the test Confirmation Confirm that the soft pedal sensor sounding position at the soft pedal moves the hammer rail to the strings by 2mm 3mm If adjustment is required set the buzzer to sound with the soft pedal sensor adjustment screw Buzzer sound Confir...

Страница 19: ...tus Operation Pedal at the rest position Pedal not depressed Display Buzzer sound Display Refer to Start up Execute Piano type selection Press the YES NO button to select t47 then press the PLAY button once to execute the test Complete Push the PLAY button once to terminate the piano type selection item Confirmation Depress the damper pedal to confirm the tone changes one after the other according...

Страница 20: ... on the display press the PLAY button once again Finish installation End indicates on display when program installation is finished Complete Unplug DC IN 12V power cord from Switch box or unplug power adaptor from the AC outlet to turn the power off for the installation mode termination Program writing Program writing starts automatically and several numbers which shows the program updating situat...

Страница 21: ...n installed GM unit MD DC IN Switch box CN2 Key sensor unit GP Shift UP Soft Pedal sensor Sosutenuto Pedal sensor Damper Pedal sensor CN1 Hammer sensor unit CN1 CN4 CN5 Grand Piano only DC IN unit AC adaptor DC IN AC adaptor Switch box Upright Piano Grand Piano 21 ...

Страница 22: ...IRCUIT BOARD ZA103600 PEDAL SENSOR UNIT LG WR310200 DAMPER PEDAL PEDAL SENSOR UNIT SG WV003000 SHIFT PEDAL PEDAL SENSOR UNIT SOG WU740200 SOSTENUTO PEDAL GM UNIT ZE297300 SH GMA CIRCUIT BOARD ZE000100 SH GMB CIRCUIT BOARD ZF689200 GP MOTOR UNIT WN661200 SWB KP CONNECTOR ASSEMBLY ZD143500 SWITCH BOX to TERMINAL CONNECTOR SWB KS CONNECTOR ASSEMBLY ZD176900 TERMINAL CONNECTOR to SENSOR UNITS SWB GM C...

Страница 23: ...RCUIT BOARD ZA103600 PEDAL SENSOR UNIT L VQ461900 DAMPER PEDAL PEDAL SENSOR UNIT SH WK149900 SOFT PEDAL PEDAL SENSOR UNIT SOC WK725500 SOSTENUTO PEDAL Sostenuto model only WD275500 ZF030700 Only U model SWB KP CONNECTOR ASSEMBLY ZD143500 SWITCH BOX to SENSOR UNITS DC PLUG CONNECTOR ASSEMBLY ZE724100 SWITCH BOX to DC IN UNIT WR527000 PA 150A WW333300 Only U model PJP PS04 POWER CORD ASSEMBLY WJ3736...

Страница 24: ......

Отзывы: