29
RX-SL100/RX-SL100RDS
RX-SL100/RX-SL100RDS
10. AD DATA CHECK/FAN TEST
This menu is used to display the A/D conversion value of
the terminals which detects panel keys of the main unit
and protection functions in % using the sub-menu. During
signal processing, the condition before execution is
maintained.
When K0/K1 menu is selected, keys become non-operable
due to detection of the values of all keys. However, it is
possible to advance to the next sub-menu by turning the
VOLUME of the main unit while in the menu select mode.
When using this function, note that turning the VOLUME
more than 2 clicks will cause the volume value to change.
* The figures in the diagram are given as reference only.
STATION
FM FACTORY PRESET DATA (MHz)
PAGE NO.
U, C
R, T, K, A, B, G, L
J
1
87.5
87.5
76.0
2
90.1
90.1
83.0
3
95.1
95.1
84.0
A/C/E
4
98.1
98.1
86.0
5
107.9
108.0
90.0
6
88.1
88.1
78.0
7
106.1
106.1
88.0
8
107.9
108.0
82.1
STATION
AM FACTORY PRESET DATA (kHz)
PAGE NO.
U, C, R, T, K
A, B, G, L
J
1
630
630
630
2
1080
1080
1080
3
1440
1440
1440
B/D
4
530
531
531
5
1710
1611
1611
6
900
900
900
7
1350
1350
1350
8
1400
1404
1404
•
PRESET STATIONS /
プリセット局
10. AD DATA CHECK/FAN TEST
本体パネルキー、プロテクションなどを検出している端子のA/D
変換の値を、サブメニューで%表示します。信号処理は実行前の
状態を維持します。
K0/K1のメニューにすると、全キーの値を検出するためキー操作
は で き な く な り ま す が 、 メ ニ ュ ー 選 択 モ ー ド 中 に 本 体 の
VOLUMEを回すことにより、次のサブメニューに進めることが
できます。このとき2クリック以上回すと、ボリューム値が変化
するので注意してください。
※図中の数値は参考例です。
DC
(プロテクションの検出)
DCプロテクションの値 (正常値26〜46)
DCは正常値を外れるとプロテクションが働き、電源オフされま
す。
DC
(protection detection)
DC protection value (Normal value: 26 to 46) U, C, A, L,
R, T, K models
(Normal value: 42 to 68) B, G models
If DC is out of the normal value range, the protection function
works to turn off the power.
(temperature detection/fan drive level)
THM: 5 0 0 % d i s p l a y o f t h e v o l t a g e b a s e d o n t h e
temperature detected value. Reference voltage : 5V
(Normal value: 0 to 272)
Fan: Current fan drive level on the left and the past fan
THM/Fan
(温度検出/ファン駆動レベル)
THM: 温度検出値で電圧の500%表示、基準電圧は5V (正常値
0〜272)
Fan: 左側は現在のファン駆動レベル、右側は過去のファン駆動
履歴
REC-OUT
Not applied to this model.
REC-OUT
このモデルには適用されません。
0〜4の5段階
5 levels from 0 to 4
UC
(D-AMPモジュール温度検出値)
D-AMPモジュールの雰囲気温度をTH661で検出します。
温度検出値の電圧を%表示、基準電圧は5V(正常値0〜59)
UC
(Detected value of D-AMP module temperature)
The ambient temperature of the D-AMP module is detected
by TH661.
The voltage is displayed in % using the detected value of
the temperature. The reference voltage is 5V. (Normal
value: 0 to 59)