6
En
The Yamaha Parametric room Acoustic Optimizer (YPAO) function detects speaker connections, measures the
distances from them to your listening position(s), and then automatically optimizes the speaker settings, such as
volume balance and acoustic parameters, to suit your room.
Preparing for YPAO
5
Optimizing the speaker settings automatically (YPAO)
TV
L
TV CH
TV
NPUT
MUTE
CODE SET
10
ENT
MEMORY
5
MOV E
ENHANCER
TUNING
PRESET
BAND
DISPLAY
RETURN
ENTER
ON
SCREEN
OPT ON
TOP MENU
MUTE
PROGRAM
VOLUME
POP UP/MENU
PURE DIRECT
STRAIGHT
NFO
SLEEP
MUS C
NET
TUNER
MA N
ZONE 2
USB
MODE
SCENE
BD
DV
TV
NET
RADIO
SOURCE
RECEIVER
HDMI
AV
AUDIO
5
6
5
V AUX
SUR DECODE
TV VOL
TV CH
TV
NPUT
MUTE
CODE SET
9
0
10
ENT
MEMORY
5
6
8
1
2
3
4
MOV E
ENHANCER
TUNING
PRESET
BAND
DISPLAY
ON
SCREEN
OPT ON
TOP MENU
MUTE
PROGRAM
VOLUME
POP UP/MENU
PURE DIRECT
STRAIGHT
NFO
SLEEP
MUS C
NET
TUNER
MA N
ZONE 2
USB
MODE
SCENE
BD
DVD
TV
NET
RADIO
SOURCE
HDMI
AV
AUDIO
5
6
5
V AUX
1
2
3
4
1
2
1
2
3
4
SUR DECODE
RECEIVER
Cursor keys
ENTER
RETURN
• During the measuring process, test tones are output at high volume. Ensure that the test
tones do not frighten small children. Also, refrain from using this function at night when it
may be a nuisance to others.
• During the measuring process, you cannot adjust the volume.
• During the measuring process, keep the room as quiet as possible.
• Do not connect headphones.
• Do not stand between the speakers and the YPAO microphone during the measurement
process (about 3 minutes).
• Move to the corner of the room or leave the room.
YPAO MIC
VOLUME
HIGH CUT
CROSSOVER/
MIN
MAX
MIN
MAX
The unit (front)
Place the YPAO microphone at your
listening position (same height as your
ears). We recommend the use of a
tripod as a microphone stand. You can
use the tripod screws to fix the
microphone in place.
YPAO microphone
Ear height
Turn on the subwoofer and set
the volume to half. If the
cross-over frequency is
adjustable, set it to maximum.
1
Connect the YPAO microphone to the
YPAO MIC jack on the front panel.
The following screen appears on the TV.
• To cancel the operation, disconnect the YPAO microphone
before starting the measurement.
2
To start the measurement, use the cursor
keys to select “Measure” and press
ENTER.
The measurement will start in 10 seconds.
The following screen appears on the TV when
the measurement finishes.
• If the cursor keys do not work, press RECEIVER and then use
the cursor keys.
• If any error message (such as E-1) or warning message (such
as W-2) appears, see “Error messages” or “Warning
messages” in “Owner’s Manual”.
• If the warning message “W-1:Out of Phase” appears, see
“If “W-1:Out of Phase” appears” (next page).