43
RSio64-D
1. Advance
preparation
1-1. Equipment
• [RSio64-D] (Subject to test)
• [RSio64-D] (Set to test jig mode)
• Ethernet (CAT5e) Straight cable: 2 pcs.
• BNC Cable: 1 pcs.
• MY CARD
MY16-EX: 4 unit. MY8-TD: 1 unit.
* Four MY16-EX are set to RSio64-D (subject of examination).
Setting of the jig (MY16-EX card)
Switches are set up as shown in a
fi
gure.
SW104
g
ON
SW105
g
OFF
SW105
SW104
OFF
OFF
MY8-TD is set to SLOT1 of RSio64-D (jig).
• PC: 1 unit, Windows Vista or Windows 7 with Ethernet port.
• Gigabit Switching Hub: 1 unit
1-2. Network
setting
[Control panel]
g
[Network connection]
g
[Local area connection]
g
[Property]
g
Select Internet Protocol (TCP/IP)
g
[Property]
1-2-1. Open the property of the internet protocol (TCP/IP).