PSR-E213/YPT-210
20
■
TEST PROGRAM
1
Preparation
1) Use an AC adaptor PA-3C or PA-32.
2) Measuring device: Frequency counter, which can detect thousandth digit, Level meter (with JIS-C filter).
Note: Connect a load resistor of 33
Ω
to the terminal [PHONES/OUTPUT]. Input impedance of the measuring device
should be 1 M
Ω
or more.
3) Jig: Foot switch (FC-4 or FC-5), MIDI cable.
2
Start-up the Test Program
Holding down the keys [C2#], [F2], [G2#] simultaneously, press the [STANDBY/ON] switch.
G
TEST
F2
C2#
2#
STANDBY/ON
3
Test Procedure
1) When the test program is started, “
TEST
” will be displayed on the LCD.
2) Press the [–] or [+] button of the number buttons to select a test program item.
3) Press the [START/STOP] button to execute the test.
If the result is OK or test item is completed
, press the [START/STOP] button again to return to the item selection
display.
Press the [–] or [+] button of the number buttons to select the next test item.
A cursor (“_”) is shown below the first character of the item for which the test results are OK.
If the results are NG
, press the lowest key in the keyboard (white key C1) to return to the item selection display.
4
Test program list
1
2
3
4
5
6
7
001 : Version
002 : Rom Chk1
011 : TG1 Chk
013 : Pit Chk
014 : Output R
015 : Output L
019 : Noise
020 : SW Chk
Displays the version of the ROM.
“[
***
]
Prog
” is displayed on the LCD.
[
***
]: Version
ROM connected to the bus of the CPU is checked.
Make sure that “
Rom OK
” is displayed on the LCD.
Plays each key automatically in the order of scale (auto-scaling). (32 notes from C2 to G4 will be played.)
Check that there is no abnormal sounds or noise. When the auto-scaling is finished, “
TG1 End
” will be shown.
Press a key to play a sound. (Single note, the key pressed first will be played.)
Connect the frequency counter to the [PHONES/OUTPUT] terminal. (Either L or R)
Checks pitch. (440.14 Hz
±
0.22 Hz)
Check that the correct signal is output.
Connect the level meter (with JIS-C filter) to the L/R terminals of the [PHONES/OUTPUT]. (33
Ω
of load)
• PHONES L: -45 dBu or less
• PHONES R: -2 dBu
±
2 dB
Connect the level meter (with JIS-C filter) to the L/R terminals of the [PHONES/OUTPUT]. (33
Ω
of load)
• PHONES L: -2 dBu
±
2 dB
• PHONES R: -45 dBu or less
This item progresses to the next without inspecting.
Checks switches on the panel. Press the switches as shown in the LCD. When the switch is pressed, a sound
is played at the prescribed pitch. (Refer to the Switch test item list.)
Make sure that “
SW OK
” is displayed on the LCD when all the switches are pressed.
To cancel the operation halfway, use the [lowest key on the keyboard] to return to the selection display.
(0 dBu = 0.775 V)
Test No. LCD display
Test descriptions, judging conditions, etc.