ENGLISH
25
1. Part Assign
..................................... Settings: In the XG Mode: 01…16, off;
In the Performance Mode: 01…04 , off
Designates the Part to which the VL voice is assigned.
■
System Parameters.....................................................................................
2. WX Lip Mode
.......................................... Settings: Norm (Normal), Expd (Expand)
WX-series Wind MIDI Controllers produce pitch bend data ranging from “-16” to
“+32” in response to lip (reed) pressure. The “WX Lip” parameter determines whether
these values are used as is (“Norm”), or expanded to a full “-64” through “+63” range
(“Expd”). The pitch bend data transmitted from the device other than WX-series can
be received.
• The VL voices cannot be assinged to several parts at one time since the PLG100-VL is monophonic.
• The “Expd” setting is recommended when using a WX controller in the “tight lip” mode. The “Norm”
setting is recommended when using the WX controller “loose lip” mode.
• The settings made here is effective only for the PLG100-VL.
VL System Parameters
Data sent to the
tone generator
-16
+32
-16
+32
0
-16
+32
-64
+63
0
Pitch Bend Range When Using a WX Controller in the “tight lip” Mode
When “Norm” is selected
When “Expd” is selected
Received
data
Data sent to the
tone generator
Received
data