![Yamaha MU5 Скачать руководство пользователя страница 62](http://html2.mh-extra.com/html/yamaha/mu5/mu5_manual-de-usuario_3400755062.webp)
11
add-
3.1.3 Channel Mode Messages
Channel Mode Messages are not transmitted.
3.1.4 RPN (Registered Parameter Number)
The RPN MSB and RPN LSB must be sent first for the desired parameter setting,
followed by the data entry values.
RPN
Data Entry
MSB LSB
MSB LSB
$00 $00
$mm
--
Pitch bend sensitivity
mm : $00 – $18 (0 – 24 semitones)
“--” : Not used
Range is two octaves, selectable in one semitone
steps. When power is turned on, this is set to two
semitones.
$00 $01
$mm $l l
Master fine tuning
(mm,l l) : ($00,$00) – ($40,$00) – ($7F,$7F)
(-8192x100/8192) – 0 – (+8192x100/8192 cents)
$00 $02
$mm
--
Master coarse tuning
mm : $28 – $40 – $58 (-24 – 0 – +24 semitones)
“--” : Not used
3.2 Reception
3.2.1 Note ON/OFF
Receive note range
= C-2 – G8
Velocity range
= 1 – 127 (Note On velocity only.)
When Receive Note Message is set to OFF, reception is disabled. When drum part
data is received, the MU5 sometimes does not respond to Note Off messages
(depending on the transmitted instrument).
3.2.2 Control Change
The following control change parameters are applicable to the MU5:
Control #
Parameter
Range
0
Bank select MSB
0 – 127
32
Bank select LSB
0
1
Modulation
0 – 127
6
Data entry MSB
0 – 127
38
Data entry LSB
0 – 127
7
Main volume
0 – 127
10
Pan
0 – 127
11
Expression
0 – 127
64
Hold 1
0 – 127
84
Portamento control
0 – 127
100
RPN LSB
0 – 127
101
RPN MSB
0 – 127
MIDI Data Format
Page 11 -
99.12.16,0:45 PM - 名称未設定