SYNTHESIZER/SEQUENCER PART
(1) TRANSMIT FLOW
MIDI <-+-[SW1]--+---------NOTE ON/OFF
9nH
OUT |
|
|
+---------KEY'S AFTER TOUCH
AnH (Seq only)
|
|
|
+---------CONTROL CHANGE (All in Seq)
|
|
MODULATION
BnH,01H
|
|
VOLUME
BnH,07H
|
|
PAN
BnH,0AH
|
|
SUSTAIN SWITCH
BnH,40H
|
|
FILTER RESONANCE
BnH,47H
|
|
EG RELEASE TIME
BnH,48H
|
|
EG ATTACK TIME
BnH,49H
|
|
FILTER CUTOFF FREQ
BnH,4AH
|
|
EG DECAY TIME
BnH,4BH
|
|
REVERB SEND
BnH,5BH
|
|
CHORUS SEND
BnH,5DH
|
|
ASSIGNABLE CONTROLLERS
BnH,(00H..5FH)
|
|
SEQ REMOTE CONTROL
BnH,(00H..7FH)
|
|
|
+--[SW7]--BANK SEL MSB
BnH,00H
|
| BANK SEL LSB
BnH,20H
|
|
|
+---------CHANNEL MODE MESSAGE (Seq only)
|
|
RESET ALL CONTROLLERS
BnH,79H
|
|
LOCAL CONTROL
BnH,7AH
|
|
OMNI MODE OFF
BnH,7CH
|
|
OMNI MODE ON
BnH,7DH
|
|
MONO MODE ON
BnH,7EH
|
|
POLY MODE ON
BnH,7FH
|
|
|
+--[SW8]--PROGRAM CHANGE
CnH
|
|
|
+---------CHANNEL AFTER TOUCH
DnH
|
|
|
+---------PITCH BEND CHANGE
EnH
|
+--[SW4]------------SYSTEM COMMON MESSAGE
|
SONG POSITION POINTER
F2H
|
SONG SELECT
F3H
|
+--[SW4]-----------SYSTEM REALTIME MESSAGE
|
TIMING CLOCK
F8H
|
START
FAH
|
CONTINUE
FBH
|
STOP
FCH
|
+-------------------ACTIVE SENSING
FEH
|
+--[SW5]-+----------SYSTEM EXCLUSIVE MESSAGE (All in Seq)
|
+--[SW6]-- <BULK DUMP>
|
|
F0H 43H 0nH 7FH 00H bhH blH ahH amH alH ddH....ddH ccH F7H
*3
|
|
|
+--[SW6]-- <PARAMETER CHANGE>
|
F0H 43H 1nH 7FH 00H ahH amH alH ddH.....ddH F7H
*3
|
+-------------------SYSTEM EXCLUSIVE MESSAGE
|
IDENTITY REPLY
|
F0H 7EH 7FH 06H 02H 43H 00H 41H 69H (or 6AH or 6BH) 05H 00H 00H
|
00H 7FH F7H
+--[SW3,4]----------MIDI MACHINE CONTROL
STOP
F0H 7FH 7FH 06H 01H F7H
DEFERRED PLAY
F0H 7FH 7FH 06H 03H F7H
LOCATE
F0H 7FH 7FH 06H 44H 06H 01H hrH
mnH scH frH ffH F7H
[SW1]
MIDI Transmit Channel
In the Master mode: complies with Zone Transmit Channel.
In the mode other than the Master: complies with Keyboard Transmit Channel.
The sequence data played back in the Song/Pattern mode is transmitted according to the MIDI Filter settings.
[SW2]
MIDI Control Mode
[SW3]
MIDI Sync (transmitted when the MIDI Sync is set to MTC.)
[SW4]
Seq MIDI Control
[SW5]
MIDI Device Number
When set to all, transmitted via 1.
The sequence data played back in the Song/Pattern mode is transmitted according to the MIDI Filter settings.
[SW6]
The System data can be transmitted/recognized in any mode.
Regarding the other types of data, it depends on the current mode whether they can be transmitted/recognized or
not.
[SW7]
SYSTEM Bank Select Switch
[SW8]
SYSTEM Program Change Switch
(2) RECEIVE FLOW
MIDI>-+-[SW10]--+---------NOTE OFF
8nH
|
|
|
+---------NOTE ON/OFF
9nH
|
|
|
+---------KEY'S AFTER TOUCH
AnH (Seq only)
|
|
|
+---------CONTROL CHANGE (All in Seq)
|
|
MODULATION
BnH,01H
|
|
PORTAMENTO TIME
BnH,05H
|
|
DATA ENTRY MSB
BnH,06H
|
|
DATA ENTRY LSB
BnH,26H
|
|
MAIN VOLUME
BnH,07H
|
|
PAN
BnH,0AH
|
|
EXPRESSION
BnH,0BH
|
|
SUSTAIN SWITCH
BnH,40H
|
|
PORTAMENTO SWITCH
BnH,41H
|
|
SOSTENUTO
BnH,42H
|
|
HARMONIC CONTENT
BnH,47H
|
|
EG RELEASE TIME
BnH,48H
|
|
EG ATTACK TIME
BnH,49H
|
|
BRIGHTNESS
BnH,4AH
|
|
EG DECAY TIME
BnH,4BH
|
|
EFFECT1 DEPTH
BnH,5BH
|
|
EFFECT3 DEPTH
BnH,5DH
|
|
DATA ENTRY INC
BnH,60H
|
|
DATA ENTRY DEC
BnH,61H
|
|
ALL SOUND OFF
BnH,78H
|
|
ASSIGNABLE CONTROLLER
BnH,(00H..5FH)
|
|
NRPN
BnH,62H,63H
*2
|
|
RPN
|
|
PITCH BEND SENS.
BnH,64H,00H,65H,00H,06H,mmH
|
|
FINE TUNING
BnH,64H,01H,65H,00H,06H,mmH,
|
|
26H,llH
|
|
COARSE TUNING
BnH,64H,02H,65H,00H,06H,mmH
|
|
RPN RESET
BnH,64H,7FH,65H,7FH
|
+--[SW2]--EG SUSTAIN LEVEL
BnH,1FH
|
|
|
+--[SW7]--BANK SEL MSB
BnH,00H
|
| BANK SEL LSB
BnH,20H
|
|
|
+---------CHANNEL MODE MESSAGE
|
|
RESET ALL CONTROLLERS
BnH,79H
|
|
LOCAL CONTROL
BnH,7AH
|
|
OMNI MODE OFF
BnH,7CH
|
|
OMNI MODE ON
BnH,7DH
|
|
MONO MODE ON
BnH,7EH
|
|
POLY MODE ON
BnH,7FH
|
|
|
+--[SW8]--PROGRAM CHANGE
CnH
|
|
|
+---------CHANNEL AFTER TOUCH
DnH
|
|
|
+---------PITCH BEND CHANGE
EnH
|
+--[SW3]------------SYSTEM COMMON MESSAGE
|
MTC QUARTER FRAME MESSAGE
F1H
|
+--[SW4]------------SYSTEM COMMON MESSAGE
|
SONG POSITION POINTER
F2H
|
SONG SELECT
F3H
|
+--[SW3]------------SYSTEM REALTIME MESSAGE
|
TIMING CLOCK
F8H
|
+--[SW4]------------SYSTEM REALTIME MESSAGE
|
START
FAH
|
CONTINUE
FBH
|
STOP
FCH
|
+-------------------ACTIVE SENSING
FEH
|
+--[SW5]-+-----+----SYSTEM EXCLUSIVE MESSAGE (All in Seq)
|
|
MIDI MASTER VOLUME
F0H 7FH 7FH 04H 01H llH mmH F7H
|
|
|
+--[SW9]---<BULK DUMP>
|
|
F0H 43H 0nH 7FH 00H bhH blH ahH amH alH ddH....ddH ccH F7H
*3
|
|
|
+--[SW6]---<PARAMETER CHANGE>
|
|
F0H 43H 1nH 7FH 00H ahH amH alH ddH.....ddH F7H
*3
|
|
|
+--[SW6]---<BULK DUMP REQUEST>
|
|
F0H 43H 2nH 7FH 00H ahH amH alH ddH.....ddH F7H
*3
|
|
|
+--[SW6]---<PARAMETER REQUEST>
|
|
F0H 43H 3nH 7FH 00H ahH amH alH F7H
*3
|
|
|
+--[SW11]--XG SYSTEM ON
|
|
F0H 43H 1nH 4CH 00H 00H 7EH 00H F7H
|
|
|
+--[SW11]--GM MODE ON
|
F0H 7EH 7FH 09H 01H F7H
|
+-------------------SYSTEM EXCLUSIVE MESSAGE
IDENTITY REQUEST
F0H 7EH 0nH 06H 01H F7H
SECTION CONTROL
F0H 43H 7EH 00H ssH 7FH F7H
(Pattern Mode only)
[SW2] MIDI
Control
Mode
[SW3]
MIDI Sync (can be set to “internal,” “MIDI,” or “MTC.”)
[SW4]
Seq MIDI Control
[SW5]
MIDI Device Number
When this is not set to off, the MIDI Master Volume can be recognized in any mode.
The sequence data played back in the Song/Pattern mode is transmitted according to the MIDI Filter settings.
[SW6]
The System data can be transmitted/recognized in any mode.
Regarding the other types of data, it depends on the current mode whether they can be transmitted/recognized or
not.
[SW7]
SYSTEM Bank Select Switch
[SW8]
SYSTEM Program Change Switch
[SW9]
SYSTEM Bulk Protect and same as SW6.
[SW10] MIDI Receive Channel and Receive Filter
In the Song/Pattern mode: complies with Part Receive Channel and Part Receive Switch.
In the other mode: complies with Basic Receive Channel.
The sequence data recorded to the Song/Pattern is recognized according to the MIDI Filter settings.
[SW11] SYSTEM Receive GM/XG On
*2: Available only for the Plug-in voices
*3: Recognized/transmitted only when the Plug-in voice (MODEL ID = 0x64) is selected.
64
Data List
MIDI Data Format