Load
208
Reference
MIDI Sync
Determines parameters related to MIDI clock and synchronization.
Determines whether Arpeggio/Motion Sequencer/Song playback will be synchronized to the instrument’s
internal clock, an external MIDI clock, or the Audio signal input from the A/D INPUT [L/MONO]/[R] jacks.
Settings:
Internal, MIDI, A/D In
Internal:
Synchronization to internal clock. You can use this setting when this tone generator is to be used alone or
as the master clock source for other equipment.
MIDI:
Synchronization to a MIDI clock received from an external MIDI instrument via MIDI. Use this setting when the
external sequencer is to be used as master.
A/D In:
Synchronization to the tempo of the Audio signal received via the A/D INPUT [L/MONO]/[R] jacks.
Clock Out
Determines whether MIDI clock messages will be transmitted or not.
Settings:
Off, On
Mode (Click Mode)
Determines the click sound (metronome) that is used during recording or playback.
Settings:
Off, Rec, Rec/Play, Always
Off:
The click will not sound.
Rec:
The click will sound during Song recording only.
Rec/Play:
The click will sound during Song recording and playback.
Always:
The click will always sound.
Precount (Click Pre-count)
Determines the number of count-in measures provided before recording actually starts after pressing the
[
R
] (Play) button while the Song recording.
Settings:
Off (Recording starts as soon as the [
R
] (Play) button is pressed), 1meas–8meas
NOTE
Since the click sound is created with the internal tone generator, using click playback affects the overall
polyphony of the instrument.
Volume (Click Volume)
Determines the click sound volume.
Settings:
0–127
Beat (Click Beat)
Determines which beats the metronome click will sound.
Settings:
1/16 (16th notes), 1/8 (8th notes), 1/4 (quarter notes), 1/2 (half notes), Whole (whole notes)
Type (Click Type)
Determines the click sound type.
Settings:
1–10
Sync Quantize (Sync Quantize Value)
Determines the actual timing at which the next Arpeggio playback starts when you trigger it while the
Arpeggio of multiple Parts is played back. When set to “off,” the next Arpeggio starts as soon as you
trigger it. The displayed number indicates the resolution in clocks.
Settings:
Off, 60 (32nd note), 80 (16th note triplet), 120 (16th note), 160 (8th note triplet), 240 (8th note), 320 (1/4 note triplet),
480 (1/4 note)
Click Out (Click Output Select)
Determines the specified output for the “Click.”
Settings:
MainL&R, USB1&2…USB7&8, USB1…USB8
MainL&R:
Outputs in stereo (two channels) to the OUTPUT [L/MONO]/[R] jacks.
USB1&2…USB7&8:
Outputs in stereo (Channels 1&2–7&8) to the [USB TO HOST] terminal.
USB1…USB8:
Outputs in mono (Channels 1–8) to the [USB TO HOST] terminal.