P S x P R T : x x x L
Notes:
•
Applying the power to this unit without correcting the abnormality can be dangerous and cause additional
circuit damage. To avoid this, if “PS” and “DC” protection function works 3 times consecutively, the power will
not turn on even when the “MAIN ZONE ” key is pressed. In order to turn on the power again, start up the self-
diagnostic function.
•
The output transistors in each amplifier channel should be checked for damage before applying power to this
unit.
•
Amplifier current should be monitored by measuring DC voltage across the emitter resistors for each channel.
Cause:
DC output of the power amplifier is abnormal.
Supplementary information:
The protection function worked due to a DC voltage appearing at the speaker terminal. A
cause could be a defect in the amplifier.
Turning on the power without correcting the abnormality will cause the protection function to work in 5 seconds and the
power supply will be shut off.
2-2. When the protection function worked due to abnormal DC output.
Cause:
The voltage in the power supply section is abnormal.
Supplementary information:
The protection function worked due to a defect or overload in the power supply.
Turning on the power without correcting the abnormality will cause the protection function to work in 1 seconds and the
power supply will be shut off.
2-3. When the protection function worked due to abnormal voltage in the power supply section.
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
H: Displayed when the voltage is HIGHER than upper limit
L: Displayed when the voltage is LOWER than lower limit
H: Displayed when the voltage is HIGHER than upper limit
L: Displayed when the voltage is LOWER than lower limit
D C P R T : x x x H
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
PS1/PS2/PS3
32
RX-V673/HTR-6065/RX-A720
RX-V673/HTR-6065/