RX-V350/HTR-5730
27
RX-V350/HTR-5730
THM/Fan
(temperature detection/fan drive level)
THM: 500% display of the voltage based on the
temperature detected value. Reference voltage :
5V (Normal value: 30 to 147)
Fan: Current fan drive level on the left and the past fan
drive history on the right.
(Not applied to these models.)
10. AD DATA CHECK/FAN TEST
This menu is used to display the A/D conversion value of
the terminals which detects panel keys of the main unit
and protection functions in % using the sub-menu. During
signal processing, the condition before execution is
maintained.
* The figures in the diagram are given as reference only.
DC/PS
(protection detection)
DC: DC protection value (Normal value: 17 to 29)
If DC is out of the normal value range, the protection
function works to turn off the power.
PS: Power supply voltage protection value (Normal value:
8 to 26)
If PS is out of the normal value range, the protection
function works to turn off the power.
REC-OUT
Not applied to these models.
IMP SW/POWER LIMIT
(Impedance/power limiter
detection)
IMP: 8 or 4 ohm impedance switch setting
(Not applied to these models.)
PL: Power limiter detection value
The voltage value of pin No. 91 of IC242 is displayed,
using 5V/256 as standard.
The port output is controlled by using the input voltage
value of pin No. 91 of IC242.
When higher than VthH, the port output is changed
from H to L.
When lower than VthL, the port output is changed from
L to H.
Note:
Vth = Threshold voltage
PORT
VthL
VthH
No.87
2.88V
3.38V U, C models
2.98V
3.48V A, B, G, E, L, R, T, K models
Display (%)
K0
K1
0 - 6
6CH INPUT
TUNING MODE
7 - 13
INPUT SELECT RIGHT
MEMORY
14 - 21
INPUT SELECT LEFT
PRESET / TUNING
22 - 31
INPUT MODE
PRESET / TUNING
32 - 41
PROGRAM
A/B/C/D/E
42 - 53
PROGRAM
FM/AM
54 - 63
BASS /
PRESET / TUNING
64 - 72
BASS / TREBLE -
PTY SEEK MODE
73 - 80
STEREO
PTY SEEK START
81 - 88
CONTROL
EON
89 - 95
SPEAKERS
RDS MODE
[Table 1]
K0/K1
(Panel key of main unit)
A/D of the key fails to function properly when the standard
value is deviated. In this case, check the constant of
partial pressure resistor, solder condition, etc. Refer to
table 1.
FAN DRIVE TEST
(Not applied to these models.)
HIGH
FAN DRIVE TEST
(Not applied to these models.)
LOW
FAN DRIVE TEST
(Not applied to these models.)
MID
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
However, it is possible to advance to the next sub-
menu by turning the VOLUME of the main unit. When
using this function, note that turning the VOLUME more
than 2 clicks will cause the volume value to change.
Содержание HTR-5730
Страница 53: ...RX V350 HTR 5730 ...