Trouble Recovery
70
6.
Insert the knotted end of the emergency
starter rope into the notch in the flywheel
rotor and wind the rope several turns
around the flywheel clockwise.
7.
Give a strong pull straight out to crank
and start the engine. Repeat if neces-
sary.
EMU29671
Engine fails to operate
EMU35321
Emergency engine operation
If the battery voltage is low or in the unlikely
event of an ignition system malfunction, the
engine speed may become erratic or the en-
gine may stop. In such a situation, follow the
procedure below.
Disconnect the yellow cord (emergency cir-
cuit) of the CDI unit.
Run the engine at low speed and return to
port.
NOTICE:
Follow this procedure only
in an emergency and just long enough to
return to port for repairs.
[ECM00381]
EMU33501
Treatment of submerged motor
If the outboard motor is submerged, immedi-
ately take it to a Yamaha dealer. Otherwise
some corrosion may begin almost immediate-
ly.
NOTICE:
Do not attempt to run the out-
board motor until it has been completely
inspected.
[ECM00401]
1. Yellow cord
U60R3BE0.book Page 70 Thursday, May 2, 2013 8:59 AM