Trouble Recovery
84
EWM00632
Substituting an incorrect fuse or a piece of
wire could allow excessive current flow.
This could cause electric system damage
and a fire hazard.
Consult your Yamaha dealer if the new fuse
immediately blows again.
EMU32134
Power tilt will not operate
EWM02331
Never get under the engine while it is tilt-
ed. Severe injury could occur if the out-
board motor accidentally falls.
If the outboard motor cannot be tilted
up/down using the power tilt unit, e.g. be-
cause of a discharged battery or a failure with
the unit itself, the outboard motor can be tilt-
ed manually.
(1) Stop the engine.
(2) Loosen the manual valve screw by turn-
ing it counterclockwise until it stops.
(3) Adjust the outboard motor to a navigable
angle, tighten the manual valve screw
clockwise, and secure the outboard mo-
tor.
EMU29534
Starter will not operate
If the starter mechanism does not operate
(the engine cannot be cranked with the start-
er), the engine can be started with an emer-
gency starter rope.
EWM01023
Use this procedure only in an emergen-
cy to return to the nearest port for re-
pairs.
1. Fuse holder
2. Fuse (10 A)
3. Spare fuse (10 A)
4. Fuse puller
1. Fuse puller
1
2
3
4
1
ZMU04337
1. Manual valve screw
1
1
1
U6FW76E0.book Page 84 Tuesday, November 23, 2021 7:37 AM
Содержание F6D
Страница 14: ...General information 8 F8FE FT8GE FT8GEP 1 2 3 U6FW76E0 book Page 8 Tuesday November 23 2021 7 37 AM ...
Страница 97: ...U6FW76E0 book Page 91 Tuesday November 23 2021 7 37 AM ...
Страница 98: ...Printed in Japan January 2022 0 5 1 CR U6FW76E0 book Page 1 Tuesday November 23 2021 7 37 AM ...