Trouble Recovery
126
7. Unscrew the filter cup from the filter
housing.
NOTICE:
Be careful not to
twist the water detection switch lead
when unscrewing the filter cup.
[ECM01960]
8. Drain the water in the filter cup by soak-
ing it up with a rag.
9. Firmly screw the filter cup onto the filter
housing.
NOTICE:
Be careful not to
twist the water detection switch lead
when screwing the filter cup onto the
filter housing.
[ECM01970]
10. Install the cover, and tighten the bolts.
11. Connect the water detection switch cou-
pler securely until a click is heard.
12. Securely attach the water detection
switch coupler to the holder.
13. Connect the lead to the holder.
14. Install the top cowling.
1. Filter cup
2. Water detection switch lead
ZMU05895
ZMU05896
1
2
Bolt tightening torque:
8 Nm (0.82 kgf-m, 5.9 ft-lb)
1. Water detection switch coupler
ZMU05895
ZMU05897
1
ZMU05898
6AW-9-38-1E0.book 126 ページ 2012年11月29日 木曜日 午後6時6分