Trouble Recovery
95
cy, be sure to keep the unused one tilted up
and operate the other engine at low speed.
NOTICE
ECM00371
If the boat is operated with one engine in
the water but not running, water may run
into the exhaust pipe due to wave action,
causing engine trouble.
TIP:
When you are maneuvering at low speed,
such as near a dock, it is recommended that
both engines be running with one in neutral
gear if possible.
EMU41882
Replacing fuse
WARNING
EWM00632
Substituting an incorrect fuse or a piece
of wire could allow excessive current
flow. This could cause electric system
damage and a fire hazard.
If a fuse has blown, replace the fuse accord-
ing to the following procedure.
1. Turn the main switch to the “
” (off)
position.
2. Remove the fuse box cover.
3. When replacing the main fuse or isolater
fuse, remove the screws, and then re-
move the fuse. Install the spare fuse,
and then tighten the screws.
4. When replacing a fuse other than the
main fuse or isolater fuse, remove the
1. Fuse box cover
2. Main fuse (100 A)
3. Isolator fuse (100 A)
4. Fuel feed pump fuse (10 A)
5. Main switch / PTT switch / Digital electronic
control ECM (Electronic control module) fuse
(20 A)
6. Shift actuator fuse (15 A)
7. Starting switch (30 A)
8. Ignition coil / Fuel injector / Variable cam-
shaft timing / Engine ECM (Electronic control
module) fuse (30 A)
9. Electric throttle valve fuse (10 A)
10. Fuel pump fuse (15 A)
11. Screw
1. Spare fuse (100 A)
2. Spare fuse (10 A, 15 A, 20 A, 30 A)
3. Fuse puller
3
1
11
10
8 9
7
6
5
4
2
ZMU07195
2
1
2
3
ZMU06961
6CE-9-74-1E0.book 95 ページ 2014年12月4日 木曜日 午前9時30分
Содержание F225F
Страница 39: ...Components 32 1 Fuel filter 1 ZMU07518 6CE 9 74 1E0 book 32 ページ 2014年12月4日 木曜日 午前9時30分 ...
Страница 109: ...6CE 9 74 1E0 book 102 ページ 2014年12月4日 木曜日 午前9時30分 ...
Страница 110: ...Printed on recycled paper Printed in Japan November 2014 0 5 1 6CE 9 74 1E0 book 1 ページ 2014年12月4日 木曜日 午前9時30分 ...