Maintenance
75
TIP:
Inspect ground leads attached to external
anodes on equipped models. Consult a
Yamaha dealer for inspection and replace-
ment of internal anodes attached to the pow-
er unit.
EMU29324
Checking battery (for electric start
models)
WARNING
EWM01903
Battery electrolyte is poisonous and
caustic, and batteries generate explosive
hydrogen gas. When working near the
battery:
Wear protective eye gear and rubber
gloves.
Do not smoke or bring any other source
of ignition near the battery.
The procedure for checking the battery var-
ies for different batteries. This procedure
contains typical checks that apply to many
batteries, but you should always refer to the
battery manufacturer’s instructions.
NOTICE
ECM01921
A poorly maintained battery will quickly
deteriorate.
1. Check the electrolyte level.
2. Check the battery’s charge. If your boat
is equipped with the digital speedome-
ter, the voltmeter and low battery alert
functions will help you monitor the bat-
tery’s charge. If the battery needs charg-
ing, consult your Yamaha dealer.
3. Check the battery connections. They
should be clean, secure, and covered by
an insulating cover.
WARNING! Bad
connections can produce shorting or
arcing and cause an explosion.
[EWM01913]
EMU29335
Connecting the battery
WARNING
EWM00573
Mount the battery holder securely in a
dry, well-ventilated, vibration-free loca-
tion in the boat. Install a fully charged bat-
tery in the holder.
NOTICE
ECM01125
Do not reverse the battery cables. Other-
wise, the electrical parts could be dam-
aged.
1. Make sure the main switch (on applica-
ble models) is “
” (off) before working
on the battery.
2. Connect the red battery cable to the
POSITIVE (+) terminal first. Then con-
nect the black battery cable to the NEG-
ATIVE (-) terminal.
6BP-9-76-1E0.book 75 ページ 2013年11月13日 水曜日 午後6時11分