39
DXR8/DXR10/DXR12/DXR15
When determination of the result based on measurement
result by operator is input, the result is displayed in output
window as shown below.
When Normal
Measurement value PASS
PASS: LINK-MUTE LEVEL
When Abnormal
Measurement value FAIL
FAIL: LINK-MUTE LEVEL
Troubleshooting
If FAIL, check parts (DSP circuit board: TR707 - TR711)
and peripheral circuitry and wire connection.
3-6. SWITCH inspection
Inspect on | off status of FRONT LED DISABLE switch.
Inspect FOH / MAIN | OFF | MONITOR status
D-CONTOUR switch.
Inspect 120 Hz | 100 Hz | OFF status of HPF switch.
Set status of each switch according to the display and click
“OK” button.
If result is FAIL, the following display for retry is dis-
played.
When “Retry” button is clicked, the test is performed
again.
When “Cancel” button is clicked, the test is not performed
again.
オペレータの計測結果に応じた結果判定を入力する
と、検査結果はアウトプット ウインドウへ下記のよ
うに表示されます。
正常時
計測値 PASS
PASS:
LINK-MUTE LEVEL
異常時
計測値 FAIL
FAIL:
LINK-MUTE LEVEL
トラブルシューティング
FAIL の場合、DSP シート上の TR707 〜 TR711 と周
辺の部品および配線を確認してください。
3-6. SWITCH 検査
FRONT LED DISABLE スイッチの ON ¦ OFF 状態を
検査します。
D-CONTOUR ス イ ッ チ の FOH / MAIN ¦ OFF ¦
MONITOR 状態を検査します。
HPF スイッチの 120 Hz ¦ 100 Hz ¦ OFF 状態を検査し
ます。
画面表示に従って各スイッチの状態を設定し、
「OK」
ボタンをクリックします。
FAIL の場合、下記の再検査用画面が表示されます。
「Retry」ボタンをクリックすると再テストが実施さ
れます。
「Cancel」ボタンをクリックすると再テストは実施
されません。
Содержание DXR Series
Страница 29: ...29 DXR8 DXR10 DXR12 DXR15 Pattern side パターン側 AMPS Circuit Board Scale 90 100 2NA WW65240 2 ...
Страница 31: ...31 DXR8 DXR10 DXR12 DXR15 2NA WW59820 3 Pattern side パターン側 DSP Circuit Board to AMPS CN255 ...
Страница 32: ...DXR8 DXR10 DXR12 DXR15 32 to AMPS CN101 SUB1 Circuit Board 2NA WW65260 4 Component side 部品側 Pattern side パターン側 ...
Страница 73: ... G O HWDLOV A 部詳細 SDUWV RI 100 の部品 7 03 66 0 TWAMP Ass y 6HH SDJH 13 DXR8 DXR10 DXR12 DXR15 ...
Страница 74: ... E E F F D F E E E E E E E D E E 6 66 0 シールド Ass y 03 29 5 66 0 アンプカバー Ass y DXR8 DXR10 DXR12 DXR15 14 ...