DVD-S520/DV-S5450
DVD-S520/DV-S5450
ERROR CODES LOOP TEST
ERROR CODE
NUCLEUS NUMBER
ERROR DESCRIPTION
0601
6
Calculated checksum of FLASH is not correct
0901
9
The DVD DRAM is faulty
1104
11
I2C bus busy before start
1102
NVRAM access time-out
1103
No NVRAM Acknowledge
1104
NVRAM reply time-out
1201
12
I2C bus busy
1202
I2C bus not working
1203
Slave controller not responding
1204
Slave response is not correct
1301
13
Parity error from basic engine to serial
1302
Parity error from serial to basic engine
1303
No communication between serial and basic engine
1304
Communication time-out error
1601
16
The SDRAM is faulty
5201
52
54
5202
Error sending I2C command to COLOR SETUP IC
Error sending I2C command to SCART SWITCH IC
Colour setup IC not responding
Colour setup IC response is not correct
SCART Switch is not responding
SCART Switch response is not correct
5203
5204
5401
5402
5403
5403
I2C bus busy
I2C bus busy
17
4. LOOP TEST
At the start of the loop test, the display will show the result
of the interactive player test:
Figure 28
The left side of the display contains a 3-digit code, which
can have a value between 000 and 111. These values are
to be interpreted as follows:
Displayed
Value
Indication for each module
Basic Engine
Mono
PCB
Display
PCB
000
ok
ok
ok
001
ok
ok
faulty
010
ok
faulty
ok
011
ok
faulty
faulty
100
faulty
ok
ok
101
faulty
ok
faulty
110
faulty
faulty
ok
111
faulty
faulty
faulty
Figure 29
The loop test will perform the same nuclei as the dealer
test, but it will loop through the list of nuclei indefinitely.
The display of the DVD player will display not only the
three digits indicating correct/faulty modules and the last
found error code (as mentioned, faults are detected as far
as they can be within the scope of the diagnostic
software), but also a loop counter indicating how many
times the loop has been gone through.
Example:
FAULTY
MODULE(S)
LOOP
COUNTER NUCLEUS ERROR
Figure 30
The number after the hyphen indicates the number of
times the loop test has been performed; the 4 digits at the
right side of the display show the last error that was found
when running the loop test: the leftmost two digits of this
code indicate which nucleus resulted in a fault; the
rightmost two digits refer to the faultcode within that
nucleus. For further explanation of this error code, see list
of error codes below.
Figure 31