RX-Z1/DSP-AZ1
RX-Z1/DSP-AZ1
19
* Additional causes of protection can be due to loose
connections, associated components, CPU, etc.
* For the protection voltage value, refer to DIAG menu
No.12 described later.
• Display during menu operation
During the DIAG operation, the menu list described in the
s e c t i o n o f t h e s t a r t u p s c r e e n a p p e a r s o n t h e
superimposed screen and the function at work is indicated
on the FL indicator. The contents displayed during the
function operation are described in the later section on
details of functions.
• Operation procedure of DIAG menu and
SUB-MENU
There are 16 MENU items, each of which has some SUB-
MENU items. DSP IF STATUS also has 21 sub-menus.
DIAG menu selection
Main unit [RX-Z1]: Select the menu using (Forward) and
(Reverse) keys of PRESET/TUNING located in the
sealing panel.
Main unit [DSP-AZ1]: Select the menu using (Forward)
and
(Reverse) keys of PROGRAM located in the
sealing panel.
Remote control unit [RAV2000Z1]: In the PARAMETER
select mode, select the DIAG menu using (Forward) and
(Reverse) keys.
Remote control unit [RAV225]: Set the select switch to the
PARAMETER side and select the DIAG menu using
∇
(Forward) and
∆
(Reverse) keys.
SUB-MENU selection
Main unit [RX-Z1]: Select the sub-menu using (Forward)
and
(Reverse) keys of PROGRAM located in the
sealing panel.
Main unit [DSP-AZ1]: Select the sub-menu using +
(Forward) and - (Reverse) keys of SET MENU located in
the sealing panel.
Remote control unit: Select the sub-menu using +
(Forward) and - (Reverse) keys.
• History of protection function
When the protection function has worked, its history is
stored in memory with a backup. Even if no abnormality
is noted while servicing the unit, an abnormality which
has occurred previously can be defined as long as the
backup data has been stored.
The history of the protection function is cleared when
DIAG is cancelled by selecting PRESET RESERVED
(Memory initialized) of DIAG menu No.11 or when the
backup data is erased.
● プロテクションの履歴
プロテクションが働いた場合、履歴をバックアップして
記憶しています。サービスのときに異常が認められなく
ても、バックアップが残っていれば、お客様のところで
起きた異常を区別できます。
プロテクションの履歴は、ダイアグメニューNo.11で
PRESET RESERVED
(メモリーの初期化)
を選んでダイ
アグを解除した場合や、バックアップが消えたときには
クリアされます。
※ 前記の異常原因の他に、コネクターのはずれやCPU周
辺などに原因がある場合があります。
※ プロテクションの電圧値に関しては、後述のダイアグメ
ニューNo.12を参照してください。
● メニュー動作中の表示
ダイアグ中、モニター画面には起動画面の項で説明したメ
ニュー一覧が表示されます。本体のFLディスプレイには動
作中の機能が表示されます。機能動作中の表示内容につい
ては、後述の機能詳細で記述します。
● ダイアグメニューとサブメニューの操作
ダイアグにはNo.1〜16のメニューがあり、そのそれぞれに
サブメニューがあります。また、DSP IF STATUSにも21
種類のサブメニューがあります。
ダイアグメニューの選択
本体キーでの操作: PROGRAM (順送り), (逆送り)
キーで選択します。
リモコンでの操作: セレクトスイッチをPARAMETER側
にした状態で、▽ (順送り), △ (逆送り)キーで選択しま
す。
サブメニューの選択
本体キーでの操作: SET MENU +
(順送り), −
(逆送り)
キーで選択します。
リモコンでの操作: + (順送り), − (逆送り)キーで選択
します。
DSP IF STATUSメニューの起動
本体キーのINPUT MODEキーを押してDSP IF STATUSメ
ニューに入ります。