124
DME4io-ES/DME8i-ES/DME8o-ES
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
Indicator
Error Action
A system error has occurred.
Execute the “Initialize DME” operation, then restart it. If the error
indicators are still indicating the error, execute the “Delete All Data”
initialization.
Data inside the internal
fl
ash
memory has been erased.
The
fi
rmware update operation may have failed. Use DME Designer
to execute the Recovery update operation.
The internal battery is
completely discharged or not
installed.
If you turn off the power to the unit, the current settings will be lost
and reset to the default values. Stop operating the unit.
A scene recall attempt has
failed.
Use DME Designer to recall the scene again.
Audio is not input or output and
is muted due to insuf
fi
cient DSP
resources.
This error sometimes occurs if you try to operate a con
fi
guration at
96 kHz that has been created with a word clock of 48 kHz. To
operate a con
fi
guration at any word clock setting, use DME Designer
to create a con
fi
guration with the word clock set to 96 kHz.
The network is not
communicating properly.
Connect the Ethernet cables properly, and make sure that the
network devices are operating correctly.
Duplicate IP addresses.
Connect your computer to the DME Satellite via USB, then set a
unique IP address.
The DME Satellite contains data
for a different device group or
no data.
Send data appropriate for the actual device con
fi
guration from DME
Designer.
Indicator
Error Action
The internal battery is almost
discharged. Your data may be
lost.
If you turn off the power to the unit, the current settings may
be lost and reset to the default values.
Stop operating the unit.
The backup battery voltage is
low.
This does not affect the operation of the unit. However, if you
continue using the unit, the settings may be lost and reset to
the default values.
L
Flashing
Lit
Flashing
Lit
Flashing
Lit
Flashing
Lit
Lit
Flashing
Flashing
Lit
Flashing
Lit
Flashing
Lit
Flashing
rapidly
Flashing
slow
ERROR MESSAGES
WARNING MESSAGES
Содержание DME4io-ES
Страница 39: ...39 DME4io ES DME8i ES DME8o ES Pattern side パターン側 DSP Circuit Board DSP 2NA WG30160 1 ...
Страница 41: ...41 DME4io ES DME8i ES DME8o ES Pattern side パターン側 AD Circuit Board DME4io ES DME8i ES AD 2NA WG30380 1 ...
Страница 43: ...43 DME4io ES DME8i ES DME8o ES DA Circuit Board DME4io ES DME8o ES Pattern side パターン側 AD 2NA WG30390 1 ...