[Undo] Button
This button provides a one-step undo function that allows you to undo a single operation and revert to
the previous state. The [Undo] button will be grayed out and inaccessible immediately after an undo
operation or after the control panel is launched.
2
Device Information
When a device that is registered for communication with the DME-N Network Driver is selected in the Target
Device List, the communication parameters for that device can be viewed and edited in the Device
Information fields.
Device Name
This is the name of the device selected in the Target Device List. The initial default settings are “UNIT1”
through “UNIT256,” but the name can be edited as required in the Device Name field.
Device IP Address
The IP address of the device selected in the Target Device List can be set via these fields. The IP
address of the DSP5D can be checked in the PREFERENCE 2 screen on the PM5D console if the DSP5D
is cascade-connected to the PM5D. If the DSP5D is used alone, refer to “Connect the DSP5D to your
computer via Ethernet” of the DSP5D owner’s manual and “Console Setup” of the PM5DV2/DSP5D Editor
owner’s manual.
n
The IP address must be set properly or communication with the device will not be possible.
Device MAC Address
The MAC (Media Access Control) address of the device selected in the Target Device List can be set via
these fields. The MAC address of each device is permanently assigned when the device is
manufactured and cannot be changed. The MAC address parameter is included to prevent data from
being sent to the wrong device if the IP address in inadvertently set incorrectly. The MAC address of the
DSP5D can be checked in the PREFERENCE 2 screen on the PM5D console if the DSP5D is cascade-
connected to the PM5D. If the DSP5D is used alone, it can be searched using the [Advanced Settings]
button after setting the IP address properly. For details on the default value of IP address, refer to
“Connect the DSP5D to your computer via Ethernet” of the DSP5D owner’s manual.
n
The MAC address must be set properly or communication with the device will not be possible.
n
The MAC address of the connected device cannot be changed.
Device Port No.
The MIDI port number of the device selected in the Target Device List can be set via this menu. The MIDI
port number also functions as device ID number. It should be set to “1” for DSP5D.
n
The MIDI port number must be set properly or communication with the device will not be possible.
[Apply] Button
Click the [Apply] button after editing the Device Name, Device IP Address, Device MAC Address, or
Device Port No. parameters to actually apply the changes. Also, devices added to the Target Device List
(
1
) by pressing the [NEW] or [DUPLICATE] buttons will only actually be registered for communication
with the DME-N Network Driver when the [Apply] button is pressed.
3
[Advanced Settings] Button
Opens the “Advanced Settings” dialog box.
This window provides access to advanced settings. For details refer to the
“Advanced Settings” Dialog Box
section.
4
[Save and Close] Button
Click the [Save and Close] button to close the “DME-N Network Driver” dialog box and save the settings. This
button is not accessible while an application that is using the DME-N Network Driver is running.
n
Click the [Cancel] button if you want to close the window without saving any changes.