background image

 

2

 

The above warning is located on the top of the unit.

 

Explanation of Graphical Symbols

 

The lightning flash with arrowhead symbol 
within an equilateral triangle is intended to alert 
the user to the presence of uninsulated 
“dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the product.

 

IMPORTANT SAFETY INSTRUCTIONS

 

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8

Do not install near any heat sources such as radiators, 
heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If 
the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10

Protect the power cord from being walked on or pinched 
particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus.

11

Only use attachments/accessories specified by the 
manufacturer.

12

Use only with the cart, stand, 
tripod, bracket, or table specified 
by the manufacturer, or sold with 
the apparatus. When a cart is 
used, use caution when moving 
the cart/apparatus combination 
to avoid injury from tip-over.

13

Unplug this apparatus during 
lightning storms or when unused for long periods of 
time.

14

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been spilled or objects have 
fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, 
or has been dropped.

 

(98-6500)

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER (OR BACK). NO USER-SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

WARNING

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

Содержание DCU5D

Страница 1: ...A ZH NL IT ES FR DE EN English Deutsch Français Español Italiano Nederlands 日本語 Owner s Manual Bedienungsanleitung Mode d emploi Manual de instrucciones Manuale di istruzioni Gebruikershandleiding 取扱説明書 ...

Страница 2: ...and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specifi...

Страница 3: ...ble If these corrective measures do not produce satisfactory results please contact the local retailer authorized to distribute this type of product If you can not locate the appropriate retailer please con tact Yamaha Corporation of America Electronic Service Division 6600 Orangethorpe Ave Buena Park CA90620 The above statements apply ONLY to those products distributed by Yamaha Corporation of Am...

Страница 4: ...blema o funcionamiento anómalo desconecte de inmediato el enchufe de la toma de corriente Si no va a utilizar el producto durante un periodo prolongado de tiempo asegúrese de desenchufar el cable de alimentación de la toma de CA de la pared Normalmente se pueden montar en bastidor varias unidades de este modelo una al lado de la otra pero si hay que montarlas con otros dispositivos que emitan much...

Страница 5: ...reloj a y desde un dispositivo externo Este conector de entrada termina a 75Ω NOTA Se puede seleccionar WORD CLOCK IN EtherSound o AES EBU como fuente principal del reloj Utilice AVS ESMonitor de AuviTran para cambiar y definir la fuente H Conectores AES EBU 1 6 Son conectores D Sub de 25 patillas que reciben o envían señales de audio en formato AES EBU En el modo de doble velocidad 88 2 96kHz sól...

Страница 6: ...na consola de mezclas digital de Yamaha utilizando un cable Ethernet CAT5 a través de dos tarjetas de sonido EtherSound de AVY16 ES AVY16 ES es una tarjeta EtherSound de AuviTran Sistema audio live di medie dimensioni Questo sistema consente a un unità NAI48 ES con unità AD8HR e DA824 di collegarsi a una console di missaggio digitale Yamaha tramite un cavo CAT5 Ethernet grazie a due schede AVY16 E...

Страница 7: ...hasta 48 entradas AES EBU y 48 salidas AES EBU entre la consola de mezclas y la caja acústica del escenario con un cable Ethernet CAT5 Collegamento FoH e stage box a lunga distanza Due unità NAI48 ES consentono di trasferire fino a 48 input AES EBU e 48 output AES EBU tra la console di missaggio e lo stage box tramite un cavo CAT5 Ethernet FoH en langeafstandsverbinding van podiumluidsprekers Twee...

Страница 8: ... In questo sistema tre unità NAI48 ES consentono di controllare in remoto sei unità AD8HR da una console di missaggio digitale Yamaha tramite un cavo CAT5 Ethernet Verbinding via afstandsbediening met AD8HR In dit systeem zorgen drie NAI48 ES apparaten ervoor dat u zes AD8HR apparaten kunt bedienen met de afstandsbediening vanaf een digitaal mengpaneel van Yamaha via een CAT5 Ethernetkabel AD8HRとの...

Страница 9: ...ouble Rate 32ch Input Output RS422 D Sub Connector 25P Female 2 2 Use a shielded cable compliant with the following specifications to prevent electromagnetic interference Wiring Cross connection with hot and cold signals twist paired Characteristic impedance 110Ω Balanced OUT EtherSound IN 100Base TX 100Base TX RJ 45 3 3 Use a RJ 45 connector compliant with Neutrik EtherCon Use a CAT5 STP Shielded...

Страница 10: ...uipment or options may not be the same in every locale please check with your Yamaha dealer European models Purchaser User Information specified in EN55103 1 and EN55103 2 Inrush Current 13A Conforms to Environments E1 E2 E3 and E4 Signal Input Ch Output Ch Open GND 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Pin Hot 1 2 3 4 5 6 7 8 9 11 10 12 13 22 23 24 25 Cold 14 15 16 17 18 19 20 21 25 14 13 1 Pin No Sign...

Страница 11: ...Memo 26 Memo ...

Страница 12: ...e Italia 88 20020 Lainate Milano Italy Tel 02 935 771 SPAIN PORTUGAL Yamaha Hazen Música S A Ctra de la Coruna km 17 200 28230 Las Rozas Madrid Spain Tel 91 639 8888 SWEDEN Yamaha Scandinavia AB J A Wettergrens Gata 1 Box 30053 S 400 43 Göteborg Sweden Tel 031 89 34 00 DENMARK YS Copenhagen Liaison Office Generatorvej 6A DK 2730 Herlev Denmark Tel 44 92 49 00 NORWAY Norsk filial av Yamaha Scandina...

Отзывы: