LATENCY 1/2
DIP switches 3 and 4 (LATENCY 1 and LATENCY 2) set the audio latency.
n
Set all CobraNet devices receiving and transmitting audio signals to the same latency.
Clock Synchronization Mode (CLOCK 1/2)
DIP switches 5 and 6 (CLOCK 1 and CLOCK 2) specify the clock synchronization mode to be
used. See "Clock Synchronization Modes" on page 12 for more information.
LATENCY 1
LATENCY 2
LATENCY
OFF
OFF
5.33 ms
OFF
ON
2.67 ms
ON
OFF
1.33 ms
ON
ON
Reserved
CLOCK 1
CLOCK 2
Clock Synchronization Mode
OFF
OFF
Network synchronization
OFF
ON
Host synchronization 1
ON
OFF
Host synchronization 2
ON
ON
Reserved