6
OUTPUT SAFE PARAMETERS
In this area you can view and edit the Recall Safe settings for all output channels. The items in this area are the same as
in the Input Safe Parameters area (
1
).
7
GLOBAL RECALL SAFE
In this area you can view and edit the Recall Safe parameters. These are not channel parameters, but CL global parame-
ters for such things as patches, DCA groups, and racks.
8
INPUT PATCH
Excludes INPUT PATCH settings from recall operations when the button is on.
9
INPUT NAME
Excludes the channel names of input channels from recall operations when the button is on.
0
HA
Excludes Head Amps of I/O rack currently connected to the CL from recall operations when the button is on.
A
CH LINK
Excludes CH LINK settings from recall operations when the button is on.
B
OUTPUT NAME
Excludes the channel names of output channels from recall operations when the button is on.
C
OUTPUT PATCH
Excludes OUTPUT PATCH settings from recall operations when the button is on.
D
DCA
These buttons exclude DCA groups from recall operations. If the ALL button is on, the LEVEL, ON, and DCA group
names will be excluded. If the LV/ON button is on, LEVEL and ON settings will be excluded.
E
GEQ RACK
Excludes GEQ rack settings from recall operations when the button is on.
F
EFFECT RACK
Excludes EFFECT rack settings from recall operations when the button is on.
G
PREMIUM RACK
Excludes PREMIUM rack settings from recall operations when the button is on.
7
6
8
C
9
B
0
A
H
J
D
I
E
F