Precautions

 

• Do not place a container with liquid or small metal 

objects on top of this unit. Liquid or metal objects 
inside this unit are a fire and electrical shock hazard.

• Do not allow water to enter this unit or allow the unit 

to become wet. Fire or electrical shock may result.

• Connect this unit’s power cord only to an AC outlet of 

the type stated in this Owner’s Manual or as marked 
on the unit. Failure to do so is a fire and electrical 
shock hazard.

• Do not scratch, bend, twist, pull, or heat the power 

cord. A damaged power cord is a fire and electrical 
shock hazard.

• Do not place heavy objects, including this unit, on top 

of the power cord. A damaged power cord is a fire and 
electrical shock hazard. In particular, be careful not to 
place heavy objects on a power cord covered by a car-
pet.

• If you notice any abnormality, such as smoke, odor, or 

noise, or if a foreign object or liquid gets inside the 
unit, turn it off immediately. Remove the power cord 
from the AC outlet. Consult your dealer for repair. 
Using the unit in this condition is a fire and electrical 
shock hazard.

• Should this unit/AC adapter/power supply be 

dropped or the cabinet be damaged, turn the power 
switch off, remove the power plug from the AC outlet, 
and contact your dealer. If you continue using the unit 
without heeding this instruction, fire or electrical 
shock may result.

• If the power cord is damaged (i.e., cut or a bare wire is 

exposed), ask your dealer for a replacement. Using the 
unit with a damaged power cord is a fire and electrical 
shock hazard.

• Do not remove the unit’s cover. You could receive an 

electrical shock. If you think internal inspection, 
maintenance, or repair is necessary, contact your 
dealer.

• Do not modify the unit. Doing so is a fire and electri-

cal shock hazard.

• When rack-mounting the unit, allow enough free 

space around the unit for normal ventilation. This 
should be: 10 cm at the sides, 15 cm behind, and 30 
cm above.

• For normal ventilation during use, remove the rear of 

the rack or open a ventilation hole.

• If the airflow is not adequate, the unit will heat up 

inside and may cause a fire.

• This unit has ventilation holes at the top, bottom, and 

rear to prevent the internal temperature rising too 
high. Do not block them. Blocked ventilation holes 
are a fire hazard. 

• Hold the power cord plug when disconnecting it from 

an AC outlet. Never pull the cord. A damaged power 
cord is a potential fire and electrical shock hazard. 

• Do not touch the power plug with wet hands. Doing 

so is a potential electrical shock hazard.

• The digital circuits of this unit may induce a slight 

noise into nearby radios and TVs. If noise occurs, 
relocate the affected equipment.

• XLR-type connectors are wired as follows: pin 1: 

ground, pin 2: hot (+), and pin 3: cold (–).

 

Rack Mounting Caution

 

If the unit is rack mounted and transported regularly, 
for example, when on a tour, we recommend that the 
rear of the unit be supported by fitting a pair metal 
brackets, one each side. The following drawing pro-
vides the information necessary to make such brack-
ets.
Note that only one bracket is shown here and the 
bracket for the other side must be bent in the opposite 
direction.

86.5

20.5

3.1

4-

ø

6.5

2-R2

R2

2-R2

R5

t = 1.6

(82.1)
76.2

44.45

31.75

5.9

0

36.5

14.5

7.5

8

0

12

134

200

0

Downloaded from: 

http://www.usersmanualguide.com/

Содержание AI8-ML8F

Страница 1: ...L8AB MIC LINE INPUT UNIT ML8F AD UNIT AD8 Owner s Manual E U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2003 Yamaha Corporation WC62520 312IPAPx x 01A0 Printed in Japan Downloaded from http www usersmanualguide com ...

Страница 2: ...ther this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lead in is 300 ohm ribbon lead change the lead in to coaxial type cable If these corrective measures do not produce satisfactory...

Страница 3: ...emove the unit s cover You could receive an electrical shock If you think internal inspection maintenance or repair is necessary contact your dealer Do not modify the unit Doing so is a fire and electri cal shock hazard When rack mounting the unit allow enough free space around the unit for normal ventilation This should be 10 cm at the sides 15 cm behind and 30 cm above For normal ventilation dur...

Страница 4: ... for the Yamaha PM1D digital audio mixing system The AI8 inputs signals to the DSP unit DSP1D DSP1D EX engine controlled via the CS1D control sur face Up to ten AI8s can be connected to each DSP1D DSP1D EX Be sure to ask an authorized Yamaha service engineer to install the card and set up the unit Never perform installation and setup by yourself UNIT NO PHANTOM MASTER ON OFF 48V POWER ON OFF 1 2 3...

Страница 5: ...fiers of the input con nectors for which the phantom power is switched on on the AI8 that has the analog input card LMY2 MLAB etc equipped with the headphone amplifier When you turn on the switch the indicator on the left of the switch lights up C POWER ON OFF Use this switch to turn the power to the AI8 on and off When the power is turned on the INPUT UNIT ID indicator lights up D CONTROL PORT sw...

Страница 6: ... Power cable length 2 1 m Cooling fan speed always fixed Accessories Connection cable 68 pin D sub half pitch x 1 Length 3m I O connectors Level Type OUTPUT A B C RS 422 D sub half pitch 68 pin connector female WORD CLOCK IN TTL 75 Ω ON OFF BNC Connector WORD CLOCK OUT TTL 75 Ω BNC Connector Card Input LMY2 ML Channel 1A or 1B 2A or 2B LMY2 MLAB Channel 1A or 1B 2A or 2B LMY4 MLF Channel 1 4 LMY4 ...

Страница 7: ...uropean Model Purchaser User information specified in EN55103 1 and EN55103 2 Inrush Current 22A Conformed Environment E1 E2 E3 and E4 455 466 8 480 430 132 3U UNIT NO PHANTOM MASTER ON OFF 48V POWER ON OFF 1 2 3 4 5 6 7 8 141 5 ANALOG INPUT BOX 9 5 unit mm Downloaded from http www usersmanualguide com ...

Страница 8: ...YAMAHA CORPORATION Pro Audio Digital Musical Instrument Division P O Box 3 Hamamatsu 430 8651 Japan Downloaded from http www usersmanualguide com ...

Страница 9: ... tv dvd and othes Manual users user manuals user guide manual owners manual instruction manual manual owner manual owner s manual guide manual operation operating manual user s manual operating instructions manual operators manual operator manual product documentation manual user maintenance brochure user reference pdf manual Downloaded from http www usersmanualguide com ...

Отзывы: