ELEC
8-15
4.Charging coil resistance
• Disconnect the CDI magneto coupler from
the wire harness.
• Connect the pocket tester (
Ω
x 1) to the
charging coil.
• Check the charging coil resistance
Tester (+) lead
➞
White
Q
Tester (–) lead
➞
Ground
W
Charging coil resistance :
0.48 ~ 0.72
Ω
at 20
°
C (68
°
F)
MEETS
SPECIFICATION
5.Connections
Check all connections in the charging system.
Refer to “WIRING DIAGRAM”.
MEETS
SPECIFICATION
Replace the rectifier/regulator.
CHARGING SYSTEM
OUT OF SPECIFICATION
Charging coil defect
➞
Replace.
POOR CONNECTIONS
Repair.
Y/R
w
-
W/R B/R
CDI
MAGNETO
햲
햳
Содержание AEROX YQ50