A3000 Guide
28
F4 = MASTER
Tuning = This sets the overall tuning in semitone steps (Coarse) or in cents (Fine).
StOut = The stereo output signal can additionally be routed to the Assignable
Outputs or to the DIG&OPT outputs. Furthermore, the total level of the stereo
output can be raised by up to 24dB.
Owner's Manual p. 298 – 299
F5 = SYSTEM
Keys = This defines the operation of both the ASSIGNABLE key and the
AUDITION key. The ASSIGNABLE key can be set to either DAMP (completely mute
the sound output), CONTROLLER RESET (reset all Controllers), KNOB CONTROL
ON/OFF (see above) or FKEY PLAY ON/OFF (see above).
The AUDITION key can be set to normal (a note is played only while the key is
held) or toggle (playback starts on first press & stops on second press).
Display = Determines whether note values are shown as names (name) or as MIDI
note numbers (number).
Page = With atModeChange you can choose whether the A3000 will always select
the first function (1st Function) or the last selected function (Last Function) when the
mode is changed. With atFuncChange you can choose whether the A3000 will
always display the first page (1stPage) or the last selected page (Last Page) after the
function is changed. Factory-set defaults are "Last Function" and "Last Page".
FreeMem = These are the amounts of free memory space for both the waveform
memory (Wave) and the parameter memory (Param).
COMMAND functions:
SAVESYS and LOADSYS let you save and load the system parameters for each
floppy disk or hard disk partition. The system parameters include all parameters of
the UTILITY functions TOTAL EQ, MASTER, SYSTEM, and MIDI.
The system parameters are retained even when the unit is switched off.
Special Hint Ø Restoring the system settings using Factory Reset
The most simple way to reset the system settings to the factory-set default values is
FACTORY RESET. This is done by pressing and holding the FUNCTION KEY 1 (PLAY –
PROGRAM) and the COMMAND key while switching on the unit (the number of t h e
software version will be displayed). Using knob 1, select the display "18: FACTORY SET",
press knob 5 (MANUAL) and confirm with YES. Then, select the EXIT page using knob 1, and
press knob 5 (MANUAL) + YES to put the A3000 in normal operating condition.
Owner's Manual p. 284 – 285, 300 – 304
F6 = MIDI
Receive = The BasicCh (normally MIDI channel 1) is used mainly for the controllers
specified in the Program (PLAY – CONTROL) and for program changes. In addition,
Samples can also be played on the Basic Channel.
Omni, aside from rare situations, should always be set to off.
The reception of program changes can be disabled by setting PgmChange = off.