REED VALVES/CRANKCASE
REED VALVES
CHECKING THE REED VALVE
ASSEMBLY
1. Check:
• Reed valve
Cracks/damage
→
Replace.
2. Measure:
• Warpage limit
a
Out of specification
→
Replace.
Warpage limit
0.2 mm (0.008 in)
5040
3. Measure:
• Reed valve stopper height
a
Out of specification
→
Replace.
Reed valve stopper height
8.1
±
0.30 mm (0.32
±
0.01 in)
5050
CRANKCASE
ASSEMBLING THE OIL SEAL
HOUSING
Install:
• Oil seal
Bearing/oil seal attachment ....
1
YB-06348, YB-41446 /
90890-06635, 90890-06630
Driver rod ..................................
2
YB-06229, YB-06071 /
90890-06606
5060