CHK
ADJ
3-49
Charging method using a variable-current (voltage) charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery
and start charging.
Is the amperage higher
than the standard charg-
ing amperage written on
the battery?
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
Adjust the voltage to obtain
the standard charging amper-
age.
Monitor the amperage for 3 ~ 5
minutes. Is the standard charg-
ing amperage exceeded?
Adjust the charging voltage
to 20 ~ 25 V.
If the amperage does not
exceed the standard charg-
ing amperage after 5 min-
utes, replace the battery.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING AND
CHARGING THE BATTERY”.
If the required charging time exceeds 5 hours, it is advisable to
check the charging amperage after 5 hours. If there is any change in
the amperage, readjust the voltage to obtain the standard charging
amperage.
Leave the battery unused for more than 30 minutes before measur-
ing its open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
Charger
Ammeter
Set the charging voltage to 16 ~
17 V. (If the charging voltage is
lower, charging will be insufficient,
if it is higher, the battery will be
over-charged.)
YES
YES
NO
NO
CHECKING AND CHARGING THE BATTERY
Содержание 2008 Raptor 250
Страница 1: ...SERVICE MANUAL YFM250RX 4D3 28197 10 LIT 11616 21 22 2008 ...
Страница 6: ......
Страница 47: ...SPEC 2 24 Oil cooler Oil hose 1 Oil hose 2 OIL FLOW DIAGRAMS ...
Страница 308: ......
Страница 309: ......
Страница 310: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...