CHECKING AND CHARGING THE BATTERY
CHK
ADJ
Relationship between the open-circuit voltage
and the charging time at 20
_
C
Open-circuit voltage (V)
These values vary with the temperature, the condition of
the battery plates, and the electrolyte level.
13.0
12.5
12.0
11.5
5
6.5
10
Charging time (hours)
NOTE:
CAUTION:
NOTE:
Since MF batteries are sealed, it is not possible
to check the charge state of the battery by mea-
suring the specific gravity of the electrolyte.
Therefore, the charge of the battery has to be
checked by measuring the voltage at the battery
terminals.
1. Remove:
S
seat
2. Disconnect:
S
battery leads
(from the battery terminals)
First, disconnect the negative lead
1
, then
the positive lead
2
.
3. Remove:
S
battery
4. Check:
S
battery charge
a. Connect a pocket tester to the battery termi-
nals.
Tester positive lead
!
battery positive
Tester positive lead
!
terminal
Tester negative lead
!
battery negative
Tester negative lead
!
terminal
S
The charge state of a MF battery can be
checked by measuring its open-circuit voltage
(i.e., the voltage when the positive terminal is
disconnected).
S
No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown in
the charts and the following example.
Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20
X
30%
–22–