IPA8200 Owner’s Manual
59
Specifications
Current Draw
1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications.
1/3 power represents program material with extremely heavy clipping.
Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz
1W = 0.860kcal/h, 1BTU = 0.252kcal
Note that Line Voltage [V] x Line Current [A] = [VA], not equals to [W].
Inrush current: 11A (100V), 13A (120V), 26A (240V)
Line Current (A)
Power (W)
Thermal Dissipation
100/120V
230/240V
In
Out
Dissipated
Btu/h
kcal/h
Idle
0.8
0.4
69
0
69
235
59
1/8 power
8
Ω
/ch
1.9
1.0
189
100
89
304
77
4
Ω
/ch
3.3
1.5
327
200
127
433
109
1/3 power
8
Ω
/ch
3.9
1.8
389
267
122
417
105
4
Ω
/ch
7.7
3.3
774
533
241
821
207