background image

IPA8200  Owner’s Manual

59

Specifications

Current Draw

1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications.
1/3 power represents program material with extremely heavy clipping.
Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz
1W = 0.860kcal/h,  1BTU = 0.252kcal
Note that Line Voltage [V]  x Line Current [A] = [VA], not equals to [W].

Inrush current: 11A (100V), 13A (120V), 26A (240V)

Line Current (A)

Power (W)

Thermal Dissipation

100/120V

230/240V

In

Out

Dissipated

Btu/h

kcal/h

Idle

0.8

0.4

69

0

69

235

59

1/8 power

8

/ch

1.9

1.0

189

100

89

304

77

4

/ch

3.3

1.5

327

200

127

433

109

1/3 power

8

/ch

3.9

1.8

389

267

122

417

105

4

/ch

7.7

3.3

774

533

241

821

207

Содержание 001PO-03C0

Страница 1: ...IPA8200 Owner s Manual 1 IT RU ES FR DE EN English Deutsch Français Español Italiano ...

Страница 2: ... Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus ...

Страница 3: ... avoid the possibility of physical injury to you or others or damage to the device or other property These precautions include but are not limited to the following Remove the electric plug from the outlet when the device is not to be used for extended periods of time or during electrical storms When removing the electric plug from the device or an outlet always hold the plug itself and not the cor...

Страница 4: ...s or connectors Do not use this device for any purpose other than driving loudspeakers Always turn the power off when the device is not in use The performance of components with moving contacts such as switches volume controls and connectors deteriorates over time Consult qualified Yamaha service personnel about replacing defective components European models Purchaser User Information specified in...

Страница 5: ...pace between them If you are mounting this device along with other types of device in an EIA standard rack the ambient temperature inside the rack may rise due to heat produced from the other devices preventing this device from performing as designed To ensure that heat does not build up inside this device you must observe the following conditions when mounting it in a rack If you mount this devic...

Страница 6: ...Input jack connections Euroblock 10 Speaker connections barrier strip 10 Troubleshooting 11 Specifications 57 General Specifications 57 Block Diagram 58 Dimensions 58 Current Draw 59 Accessories Please make sure the following items are included in the package IPA8200 Owner s Manual this document Power cable 2 5 m x 1 Security cover x 1 Allen wrench x 1 Security cover attachment screws x 2 Eurobloc...

Страница 7: ...ate these knobs use a slotted screwdriver with a blade no wider than 5 5 mm y MUTE indicator This will light red when mute is activated u MUTE switch This turns muting on off for each channel Use a thin rod to turn muting on off i PARALLEL indicator This will light orange when the rear panel MODE switch is set to PARALLEL o BRIDGE indicator This will light orange when the rear panel MODE switch is...

Страница 8: ...s will be input to the adjacent channels A B C D E F G H as well r GAIN switch This switches the input sensitivity gain for all channels together 4 dBu Sets the input sensitivity to 4 dBu 26 dB Sets the gain to 26 dB 32 dB Sets the gain to 32 dB t HPF switch Turns the high pass filter 20 Hz or 55 Hz on off If this is set to 20 Hz or 55 Hz the frequency components below that frequency will be cut b...

Страница 9: ... channels can be used as an input connector You can use the front panel atten uators to adjust the attenuation for each channel indepen dently Total speaker impedance must be 4 8Ω If the rear panel MODE switch is set to BRIDGE the ampli fiers will be bridged between adjacent pairs of channels A B C D E F G H and the IPA8200 will operate as a high power amplifier Either of adjacent two channels can...

Страница 10: ...F H Input jack connections Euroblock Cable preparation To prepare the cable for attachment to a Euroblock con nector strip the wire as shown in the illustration and use stranded wire to make connections With a Euroblock connection the stranded wire may be prone to breakage because of metal fatigue due to the weight of the cable or due to vibration When rack mounting your equipment use a lacing bar...

Страница 11: ...ject the power amp and power supply The power amp section s heat sink temperature has exceeded 95 C or the power supply section s heat sink temperature has exceeded 85 C Check whether there might be blockage at the air intake or a ventilation problem inside the rack and verify that the load impedance of the connected speakers is not below the rated value 4Ω or 8Ω BRIDGE Then wait until the unit s ...

Страница 12: ...nel MODE switch STEREO BRIDGE PARALLEL x 4 GAIN switch 4dBu 26dB 32dB x 1 HPF switch OFF 20Hz 55Hz x 1 Connectors Input Euroblock balanced ch Output Barrier strip ch Power AC inlet x 1 Indicators POWER x 1 Green PROTECT x 8 Red CLIP x 8 Red SIGNAL x 8 Green MUTE x 8 Red PARALLEL x 4 Orange BRIDGE x 4 Orange Load Protection POWER switch on off Output mute DC fault Power supply shutdown Amplifier Pr...

Страница 13: ...RIDGE STEREO BRIDGE PARALLEL STEREO BRIDGE PARALLEL PARALLEL G CH A C E G G CH B D F H HPF HPF Comp HPF Fc 55Hz HPF Fc 20Hz HPF Fc 55Hz HPF Fc 20Hz Comp Clip Level Detect Level Detect Signal Level Detect Signal Level Detect BA Inv P Amp P Amp A C E G B D F H SPEAKERS Output Filter Unit mm inch 480 18 7 8 377 7 14 7 8 406 5 16 88 3 7 16 ...

Страница 14: ... Noise bandwidth limited from 22Hz to 22kHz 1W 0 860kcal h 1BTU 0 252kcal Note that Line Voltage V x Line Current A VA not equals to W Inrush current 11A 100V 13A 120V 26A 240V Line Current A Power W Thermal Dissipation 100 120V 230 240V In Out Dissipated Btu h kcal h Idle 0 8 0 4 69 0 69 235 59 1 8 power 8Ω ch 1 9 1 0 189 100 89 304 77 4Ω ch 3 3 1 5 327 200 127 433 109 1 3 power 8Ω ch 3 9 1 8 389...

Страница 15: ...IPA8200 Owner s Manual 60 MEMO ...

Страница 16: ...eräte kontaktieren Sie bitte Ihre örtliche Stadt oder Gemeindeverwaltung Ihren Abfallentsorgungsdienst oder die Verkaufsstelle der Artikel Information für geschäftliche Anwender in der Europäischen Union Wenn Sie Elektrogeräte ausrangieren möchten kontaktieren Sie bitte Ihren Händler oder Zulieferer für weitere Informationen Entsorgungsinformation für Länder außerhalb der Europäischen Union Dieses...

Страница 17: ... contacte a sus autorida des locales y pregunte por el método correcto de disposición Informazioni per gli utenti sulla raccolta e lo smaltimento di vecchia attrezzatura Questo simbolo sui prodotti sull imballaggio e o sui documenti che li accompagnano significa che i prodotti elettriche e elettro niche non dovrebbero essere mischiati con i rifiuti domestici generici Per il trattamento recupero e ...

Страница 18: ...58 040 FRANCE Yamaha Musique France BP 70 77312 Marne la Vallée Cedex 2 France Tel 01 64 61 4000 ITALY Yamaha Musica Italia S P A Combo Division Viale Italia 88 20020 Lainate Milano Italy Tel 02 935 771 SPAIN PORTUGAL Yamaha Música Ibérica S A Ctra de la Coruna km 17 200 28230 Las Rozas Madrid Spain Tel 91 639 8888 SWEDEN Yamaha Scandinavia AB J A Wettergrens Gata 1 Box 30053 S 400 43 Göteborg Swe...

Страница 19: ...ro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manual U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2009 Yamaha Corporation 001PO 03C0 ...

Отзывы: