5
Fig.12
Fig.13
3. How to Use
WARNING
- Do not operate the gun lever with the discharge port facing to another person during machine operation
in any case. A direct hit against the human body may result in an accident such as skin damage.
- The maximum supply air pressure of this machine is 0.7MPa. Using the machine with a supply air
pressure exceeding this limit will lead to death or bodily injury or physical damage due to machine
breakage. Be sure to adjust the supply air pressure below 0.7MPa.
- After the end of daily work, at night, and on holidays, be sure to shut off the supply air to this machine to
release the gun so as to bleed the internal pressure. Any secondary accident such as pollution of
installation, due to pump operation driven by worn-away packing or hose without shutting off the supply
air, shall be attributable to the user’s responsibility.
- During machine operation or after completion of movement, be sure to lock the caster brake for
locking.
- When the lift stops due to a foreign object caught in the sliding part, be sure to move the lift to the
opposite direction BEFORE removing an object. The lift may suddenly start moving if a foreign object is
removed directly.
1) Adjust the air regulator for the lift to set the pointer of the pressure
gauge so that it can indicate a value from 0.4MPa to 0.5MPa with
following the description of “NOTE” below. (Fig.12)
<
NOTE
>
- If the viscosity of the material is high or climate is cold, please switch
the control of the lift up/down switch to “PRESS”. Pressure can be
adjusted by the air regulator for the lift in accordance with the
viscosity of the material (up to 0.7MPa). If the pressure is too high,
the material may leak from packing of the inductor plate. Please set
the optimum pressure while operating (if the work is aborted, switch
the control of the lift up/down switch to “DOWN”).
- Material viscosity varies with changes in temperature. It is
recommended to make a note of appropriate pressure for each
season.
2) Adjust the air regulator for the pump to set the pressure supplied to
the pump to 0.2MPa to 0.7MPa. (Fig.13)
3) When you open the valve located at the end of the hose, grease is
discharged and the pump automatically starts operating. Check to
see if grease is discharged normally before using the machine.
4) Once you close the valve, the pump will stop discharging grease
and automatically stop running. As long as air is supplied, the pump
discharges the desired amount of grease by opening the valve.
5) If the pump starts operating wildly during work, there may be no
grease in the set pail or the pump may operate without discharging
any grease due to an air pocket generated. Stop operating the pump
immediately, and inspect it.
6) After finishing your work, be sure to stop supplying air to the
machine, and open the valve of the grease discharge outlet (a little
amount of grease is discharged) to release the pressure from the
hose and pump.