background image

Fig.12 

Fig.13 

 

3. How to Use 

WARNING 

-  Do not operate the gun lever with the discharge port facing to another person during machine operation 

in any case. A direct hit against the human body may result in an accident such as skin damage. 

-  The maximum supply air pressure of this machine is 0.7MPa. Using the machine with a supply air 

pressure exceeding this limit will lead to death or bodily injury or physical damage due to machine 
breakage. Be sure to adjust the supply air pressure below 0.7MPa. 

-  After the end of daily work, at night, and on holidays, be sure to shut off the supply air to this machine to 

release the gun so as to bleed the internal pressure. Any secondary accident such as pollution of 
installation, due to pump operation driven by worn-away packing or hose without shutting off the supply 
air, shall be attributable to the user’s responsibility. 

-  During machine operation or after completion of movement, be sure to lock the caster brake for 

locking. 

-  When the lift stops due to a foreign object caught in the sliding part, be sure to move the lift to the 

opposite direction BEFORE removing an object. The lift may suddenly start moving if a foreign object is 
removed directly. 

 

1)  Adjust the air regulator for the lift to set the pointer of the pressure 

gauge so that it can indicate a value from 0.4MPa to 0.5MPa with 
following the description of “NOTE” below. (Fig.12) 

 

NOTE

 

-  If the viscosity of the material is high or climate is cold, please switch 

the control of the lift up/down switch to “PRESS”. Pressure can be 
adjusted by the air regulator for the lift in accordance with the 
viscosity of the material (up to 0.7MPa). If the pressure is too high, 
the material may leak from packing of the inductor plate. Please set 
the optimum pressure while operating (if the work is aborted, switch 
the control of the lift up/down switch to “DOWN”). 

-  Material viscosity varies with changes in temperature. It is 

recommended to make a note of appropriate pressure for each 
season. 

 

2)  Adjust the air regulator for the pump to set the pressure supplied to 

the pump to 0.2MPa to 0.7MPa. (Fig.13) 

 
3)  When you open the valve located at the end of the hose, grease is 

discharged and the pump automatically starts operating. Check to 
see if grease is discharged normally before using the machine. 

 
4)  Once you close the valve, the pump will stop discharging grease 

and automatically stop running. As long as air is supplied, the pump 
discharges the desired amount of grease by opening the valve. 

 
5)  If the pump starts operating wildly during work, there may be no 

grease in the set pail or the pump may operate without discharging 
any grease due to an air pocket generated. Stop operating the pump 
immediately, and inspect it. 

 
6)  After finishing your work, be sure to stop supplying air to the 

machine, and open the valve of the grease discharge outlet (a little 
amount of grease is discharged) to release the pressure from the 
hose and pump. 

 

Содержание SKR110A50PAL-SL

Страница 1: ...R110A50PAL MODEL No 881122 SKR110A50PAL SL MODEL No 881123 WARNING Prior to operating this pump be sure to read this operation manual for safety After reading the manual please keep it at hand any tim...

Страница 2: ......

Страница 3: ...ollowing description In this manual warnings and cautions are indicated by using symbols These symbols are intended to prevent death or serious injury that may be caused to the operator or those who a...

Страница 4: ...expected movement of this product Also do not use or leave this product in a slope or any unstable locations The product if not locked may move unpredictably causing property damage or facility pollut...

Страница 5: ...s product to avoid tripping over the base and casters Be careful about your hands when installing a pail The edges of the cabinet and pail may cause hand injury Also be careful about your posture when...

Страница 6: ...2 2 2 Setting a grease pail 2 2 3 Bleeding air from grease 4 3 How to Use 5 3 1 Operation for using a high pressure grease gun 6 3 2 Replacing a grease pail 6 4 Maintenance and Inspection 4 1 Troubles...

Страница 7: ...2 Contents of Package The main devices and the accessories are packed in different cases Open the top part of the corrugated fiberboard case and check if the devices is not damaged and if accessories...

Страница 8: ...ease gun or metering valve can be attached to the hose outlet Select and purchase appropriate dispensing equipment depending on the intended use 6 Attach the supplied air coupler onto the air hose con...

Страница 9: ...not set a pail properly grease is not discharged Be sure to set it on the correct position 7 Switch the control of the lift up down switch to DOWN The lift slowly moves down due to the pump s own wei...

Страница 10: ...utlet is closed 2 Open the air valve and turn the control of pump air regulator gradually to the right clockwise The pump will start at 0 2MPa and run for a while until the pump and hose are filled wi...

Страница 11: ...tion of NOTE below Fig 12 NOTE If the viscosity of the material is high or climate is cold please switch the control of the lift up down switch to PRESS Pressure can be adjusted by the air regulator f...

Страница 12: ...sure and the chuck can be easily removed Fig 15 6 As long as the grease gun is left under pressure you can do a grease job by pulling the lever of the gun 3 2 Replacing a grease pail 1 When the amount...

Страница 13: ...re damaged Replace damaged part or remove foreign object Seat surface of foot valve in lower pump is defective wear of seat surface inclusion of foreign material Replace damaged part or remove foreign...

Страница 14: ...disassembled If disassembly is required ask the dealer to disassemble the air pump WARNING Gasoline is a high volatile fuel Do not use it to clean the pump in any case otherwise ignition or explosion...

Страница 15: ...The piston and connecting rod assembly can be pulled out Fig 20 11 Pull out the spring pin that connects between the connecting rod and the plunger and take out the plunger Wash the plunger and check...

Страница 16: ...t pin 1 No Description Q ty Parts No 881122 881123 1 851728 851999 Pump assembly 1 2 800431 Check valve assembly 1 3 619145 Bolt 5 4 631420 Spring lock washer 11 5 833029 Bleeder plug 1 6 804941 Regul...

Страница 17: ...ALS OPERATING AIR PRESSURE MAXIMUM OPERATING NOISE 80 dB WEIGHT 1 Measurement method of A weighted sound pressure level is based on ISO 1996 2 Measurement method of A weighted sound power level is bas...

Страница 18: ...enriches our repair services After filling it send it to us Trouble Information Fax Form Company name Name Address Department name Contact information Tel Fax Product name Model Duration of use 20 ye...

Страница 19: ...ith a fluid that may cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or auth...

Страница 20: ...TION INTERNATIONAL DEPARTMENT No 1 3 1 Chome Mimami Magome Ohta Ku Tokyo 143 8504 Japan PHONE 81 0 3 3777 0241 FAX 81 0 3 3777 0584 YAMADA EUROPE B V Aquamarijnstraat 50 7554 NS Hengelo 0 The Netherla...