8
⑥
Unscrew to remove the gland bushing and remove the rod and
O ring from the body. (Fig.10)
⑦
Unscrew to remove the grip and remove the O ring.
⑧
Remove the valve seat, O ring, side ring, and ball from the body.
7-2. Assembly
①
Put the parts on the bottom hole of the body in the following order:
valve seat, O ring, side ring with ball inside, o ring, and valve set.
Then securely tighten the grip with o ring attached.
②
Put the O ring on the upper hole of the body first, then screw the
gland bushing tightly, and finally insert the rod.
③
Attach the retaining ring, washer, and link in this order to one side
of the pivot pin and insert the pin into body. Then secure the other
side with the link, washer, and the retaining ring.
④
Attach the adjustment screw to the lever and secure it with a lock
nut.
⑤
Set the hook first and then the lever to the inside of the link. Then,
secure with the pivot pin attached on
③
above. Be sure to fit the
rod head in the tapered hole of the adjustment screw. If failed, the
lever will not work.
⑥
Screw to insert the connector with the nozzle attached into the body
through the hole on the side of the lever.
⑦
Insert the o ring to the side hole of the body and securely tighten
the metering cylinder.
CAUTION
- When reassembling the disassembled meter valve, be sure to replace O Rings and Packings with new
ones at the same time as defective parts.
Fig.10
O ring
O ring
Grip
Valve seat
Side ring
O ring
Retaining ring
Washer
Link
Rod
O ring
Ball valve
Valve seat
Gland bushing
Pivot pin
Retaining ring
Washer
Link