6
6. Guide Bush
6.1 Removal
▪
Remove the diaphragm and center rod etc. (see “5.1
Removal”).
▪
Remove 8 mounting bolts from the air chamber and remove
the air chamber and the gasket. [Fig.6.1]
▪
Draw out the guide bush A, B, C. [Fig.6.1]
6.2 Inspection
▪
Guide bush [Fig.6.2]
Measure the inside diameter, and if it is outside the usable
range, replace the guide bush.
Usable range of guide bush
Guide bush A, C
φ
18.4 -
φ
18.7 mm
Guide bush B
φ
18.3 -
φ
18.6 mm
▪
O ring
If the O ring is worn out or cracked, replace it.
6.3 Installation
For installation, see [Exploded View] on the separate sheet and install in the reverse order of disassembly.
Tightening torque for air chamber retainer bolts
18 N•m
<NOTE>
▪
Make sure there is no dust on the seal surface and the seal
is not damaged.
▪
Apply grease to O ring.
▪
Fill the inside diameter groove of the guide bush B with
grease.
Fig.6.1
<
Guide bush
A
>
<
Guide bush
B
>
<
Guide bush
C
>
Fig.6.2