YAMADA 40 Series Скачать руководство пользователя страница 8

 

3.1 Pump installation 

1

 Refer to Fig. 4 for mounting dimensions of the pump. Make sure the environment to install the pump satisfies the 

following conditions: 
- A flat surface indoor (area where exhaust from the pump does not affect peripheral equipment) 
- Enough space to perform maintenance 

 
 
 
 
 
 
 
 
 
 

 

2

 Lift the pump using the eye nut on the top. Put the mounting plate on a mount. Align the holes on the mounting 

plate with the screw holes on the mount and secure it using four bolts with wave spring washers. 

<Installing on a stationary mount> 

Secure a mount to the floor using anchor bolts to prevent a fall due to pump vibration. 

<Installing on a movable mount> 

Keep the pump from moving or falling due to pump vibration by securing a mount with a locking device like a 
stopper. 

 

3.2  Installation of nylon tube 

Please correctly install the nylon tube to the pump by referring to Fig. 1 of "1.1 Part Names". 
Then please make sure to insert the nylon tube into the fitting as deeply as possible. After the installation, please 
make sure that the nylon tube is firmly connected by lightly pulling it. 

 

3.3  Installation of silencer 

CAUTION 

Each connection is capped. Remove the caps all. 
 

Wrap sealing tape around the silencer thread to prevent leakage. 

 

Attach the silencer to the pump and secure it using a tool. (Fig. 5) 

 

Wrap sealing tape around the silencer thread to prevent leakage. 
 

 
 
 
 
 

3.4  Connecting suction piping 

(connecting pump to inductor plate)

 

1

 Insert the lower part of the pump through the gasket into the inductor 

plate. 

2

 Rotate the holes in the gasket and flanged part of the pump to align 

with the bolt holes in the inductor plate. Insert bolts with wave spring 
washers through each hole and tighten them securely. Make sure 
the air release plug is positioned in the front side of the pump facing 
away from the bleeder valve. 

Fig. 4

 Pump mounting dimension 

Bolt 

Gasket 

Inductor

 

plate 

Fig. 6 

Connecting pump to inductor plate 

Pump 

SR140P25

38

50-P

SR140P25

38

50-D

SR125D13

170

210

φ

160

φ

160

C

P.C.D.200

P.C.D.265

D

(mounting hole)

4-

φ

10

4-

φ

10

A

(Dimension of mounting plate)

B

(Mounting diameter of pump)

Bolt hole

Fig. 5

   

Silencer 

Содержание 40 Series

Страница 1: ...SR140P50 P MODEL No 854559 50 1 SR140P25 D MODEL No 854560 25 1 SR140P38 D MODEL No 854561 38 1 SR140P50 D MODEL No 854562 50 1 SR125D13 MODEL No 854664 13 1 WARNING Prior to operating this pump be s...

Страница 2: ...ings and Cautions To use this product safely be sure to observe the contents of the following description In this manual warnings and cautions are indicated by using symbols These symbols are intended...

Страница 3: ...erty damage Be sure to use the unit in accordance with the specifications described in 7 Specifications in this manual Installation and piping Ground connection Make ground connection to pump and peri...

Страница 4: ...or breakage Do not plumb directly Do not connect the material outlet and piping directly Attach a flexible tube like a hose to connect the pump to the piping The pump if connected directly to the pipi...

Страница 5: ...Connecting suction piping 4 3 6 Discharge piping 4 3 7 Air piping 4 3 8 Preparation for use 4 3 9 Connecting the ground wire 5 4 Operating Method 4 1 Description of valve 5 4 2 Solvent cup 5 4 3 Filli...

Страница 6: ...are loose The nylon tube and the silencer are detached from the pump in the packaging due to the shipping conditions 2 Operating principle Yamada s air powered pumps employ reciprocating motion syste...

Страница 7: ...ion Use a stopper caster wheel with a brake or other locking device to prevent a mount from moving due to reciprocating pump vibration Before installing the pump verify that the shovel at the bottom i...

Страница 8: ...ng as deeply as possible After the installation please make sure that the nylon tube is firmly connected by lightly pulling it 3 3 Installation of silencer CAUTION Each connection is capped Remove the...

Страница 9: ...material outlet 2 Connect the other end of the hose to a delivery pipeline Attach a valve at the connection between the hose and the piping for maintenance and keep it closed until unit installation i...

Страница 10: ...e the pump only as necessary Avoid allowing the pump to run dry as much as possible The life expectancy of packings will be reduced The pump runs dry when a container becomes empty Stop the pump immed...

Страница 11: ...al from the outlet Once the air in the piping is released completely close the air valve for the pump and set the pump air regulator to 0MPa The pump is now ready for operation 2 Adjust the pump air r...

Страница 12: ...ng pump operation and There is no abrasion or deterioration apparently in each part of the pump Lubricate pump Lubricate pump according to the following procedure Close the air valve for the pump and...

Страница 13: ...ve is defective wear of seat surface inclusion of foreign material or packings are damaged If downward movement of plunger is faster seat surface of foot valve is defective wear of seat surface inclus...

Страница 14: ...804815 716246 Valve seat 1 per unit 10 million cycles Block 1 per unit 10 million cycles Spring 1 per unit 10 million cycles Ball 1 per unit 10 million cycles O ring 1 per unit 5 million cycles O ring...

Страница 15: ...nal injury or property damage Pump 10 years Standard Conditions of Use SR140P25 SR140P38 SR140P50 SR125D13 Application Season Temperature Material being pumped Supply air pressure Daily Amount of Mate...

Страница 16: ...1 632059 3 Slit pin 5 716288 Joint 1 6 716289 Connecting rod 1 7 716286 716290 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804816 804817 804818 804816 804817 804818 Lower pump assembly 1 1...

Страница 17: ...1 2 716409 Bushing 1 3 700350 Cap nut 1 4 632059 Slit pin 3 5 716288 Joint 1 6 716597 Connecting rod 1 7 716290 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804956 Lower pump assembly 1 11 7...

Страница 18: ...7 640132 O ring 1 10 38 716309 Foot valve housing 1 10 39 640015 O ring 2 10 40 685617 Pin 1 10 41 640020 O ring 1 10 42 715260 Piston body 1 10 43 685618 U packing 2 10 44 685619 Backup ring 2 10 45...

Страница 19: ...t 1 10 37 640132 O ring 1 10 38 716316 Foot valve housing 1 10 39 686305 O ring 2 10 40 632544 632543 Pin 1 10 41 640016 640015 O ring 1 10 42 715568 715576 Piston body 1 10 43 685787 685792 U packing...

Страница 20: ...valve housing 1 10 15 640135 O ring 2 10 16 701542 Stopper 1 10 17 713550 Foot valve 1 10 18 701538 Shovel rod 1 10 19 701539 Shovel 1 10 20 631916 Wave spring washer 1 10 21 627012 Nut 1 10 22 83301...

Страница 21: ...nd drum pump respectively 3 Measurement method of A weighted sound pressure level is based on ISO 1996 4 Measurement method of A weighted sound power level is based on ISO 3744 0 2 0 7 MPa Rc3 8 Equip...

Страница 22: ...NOTE Avoid continuous operation if a desired discharge volume is in the shaded area in the right side of each figure SR140P50 Performance curve SR140P25 Performance curve SR140P38 Performance curve SR...

Страница 23: ...cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or authorized service perso...

Страница 24: ...8504 Japan PHONE 81 0 3 3777 0241 FAX 81 0 3 3777 0584 E mail intl yamadacorp co jp Web www yamadacorp co jp YAMADA THAILAND CO LTD 41 79 Moo 6 Bangcha long Bangplee Sumutprakarn10540 Thailand PHONE 6...

Отзывы: