9
8. Specification
■
Specification
■
Performance Curve
<Note>
The continuous pump operation should be avoided if the desired delivery is in the range shaded in the figure
below.
PD-110B5
・
SH-110B5
・
DR-110B5 SH-110B5
SUS
・
DR-110B5 SUS
PD-110B5
SH-110B5
DR-110B5 SH-110B5 SUS DR-110B5 SUS
851829
851830
851831
851832
851833
SUCTION PORT
R 1-1/2
R 1-1/2
DISCHARGE PORT
AIR CONNECTION SUPPLY PORT
A-WEIGHTED SOUND
PRESSURE LEVEL *1
A-WEIGHTED SOUND
POWER LEVEL *2
ENV. TEMPERATURE
MATERIAL TEMP.
14.1 kg
12.0 kg
17.0 kg
15.0 kg
16.0 kg
*1 Measurement method of A-weighted sound pressure level is based on ISO 1996.
*2 Measurement method of A-weighted sound power level is based on ISO 3744.
*3 Discharge volume (per cycle) varies according to use conditions.
90 dB
101 dB
0 ~ 60
℃
100mL
0 ~ 80
℃
60 mm
5 x 1
Rc 3/4
G 1/4(F) (Union Adapter)
0.3 ~ 0.7 MPa
WEIGHT
TYPE
MODEL No.
PUMP RATIO (NOMINAL)
FLUID
CONNECTION
OPERATING AIR PRESSURE
MAXIMUM
OPERATING NOISE
AMB. TEMP.
RANGE
98 mL
MAXIMUM DISCHARGE PRESSURE
STROKE (NOMINAL)
DISCHARGE VOLUME per CYCLE *3
3.5 MPa
Содержание 110 Series
Страница 17: ...MEMO ...