2.
Special Setting
In the special setting, the setting of output voltage and green mode
(saving energy mode) can be set .
2-1
The setting of output voltage
It
can be set up by special setting as the following table.
(The method of setting can be shown P11
~
16)
ALS-
△△
KH
200V
220V
230V
240V
ALS-
△△
K
100V
110V
115V
120V
2-2
The setting of Green Mode.
The green mode is the saving energy mode that bypass
operation is done at the time of the low load.
(The method of setting can be shown P17)
ALS-1.5K / -1.5KH
ALS-2K / -2KH
ALS-3K / -3KH
30W or less
60W or less
90W or less
Be careful enough of the setup because a backup by the
battery isn't completed when AC line is failed during
green mode operation.
■
The method of Special Setting.
Push a FUNCTION key and a SET key in the bottom left of the
front panel for more than one second at the same time.
●
Every time a FUNCTION key is pushed,
LED
①
-
⑦
are turned on in turn.
●
Every time a SET key is pushed, LED
⑧
repeats lighting, lights-out.
●
The setting, confirmation of the output voltage
can be done with a combination of the lighting,
lights-out with LED
①②
and
⑧
, and the setting,
confirmation of the green mode can be done with
the combination of the lighting, lights-out with
LED
④
and
⑧
.
11