EN_Product manual_Toro_v1.2
- 5 -
Mains power
The Toro can be installed on mains power (230V AC).
Every Toro comes with an adapter to connect the 230V to. It is important to use a double shielded
power cable for safety reasons, and have this installed on a separate group. The type of power cable to
use: Ymvk ground cable, 2 cores, 2,5mm².
Electronics
To ensure electrical safety, the power cable is double insulated and the Toro electronic parts operate at
a safe low voltage (max 15V). All electronic parts are incorporated in the Toro construction and stored
waterproof (IP65).
•
The Toro needs to be powered by 230V AC (110 V.) AC
•
The connection load of the Toro is 230V (110 V.), 5A
•
The power cable (ground cable, possibly in protective tube) should be lead through the Toro
construction to the mounting panel with the electronic parts
•
The power cable needs to be connected to the power socket on the mounting panel by a certified
electronic engineer
•
The power cable needs to be assembled in the blue power socket norm 2P + earth contact box
of class IP44. This power supply MUST be assembled on separate group with a 30mA ground
fault circuit interrupter (GFCI), fused on 10A or 16A. For example with a protection box of the
type:
Merlin Gerin
MG 10A-B 19791 DPNA VIGI 30MA
( Technische Unie nr.: 322420 )
Master goal - Backside
Connection
ground cable-
power socket
Power (ground) cable.
230V(110V) AC on separated
group with ground fault circuit
interrupter (GFCI)