7 Electronics: Information
To ensure electric safety, the power cable is double insulated and the Memo electronic parts operate at
a low voltage (max 15V). All electronic parts are incorporated in the Memo construction and stored wa-
terproof (IP65).
-
The Memo needs to be powered by 230V AC and runs on 2A.
-
The power cable (ground cable, possibly in protective tube) should be lead through the Memo
construction to the mounting panel with the electronic parts.
-
The power cable needs to be connected to the power socket on the mounting panel by a certified
electrician.
-
Solely use the supplied cable (Ecomate to power net) be used between the power socket and
the safety transformer
-
The power cable needs to be connected to the blue power socket norm 2P + earth
contact box of class IP44. This power supply MUST be assembled on separate group with a
30mA ground fault circuit interrupter (GFCI), fused on 10A or 16A. For example with a
protection box of the type: Merlin Gerin, MG 10A-B 19791 DPNA VIGI 30MA
Power (ground) cable. 230V AC on
seperated group with ground fault
circuit interrupter
Connection gound
cable to power socket