background image

User‘s manual

Uživatelská p

ř

íru

č

ka

Používate

ľ

ská príru

č

ka

Felhasználói kézikönyv

Instrukcja u

ż

ytkownika

METEOROLOGICKÁ STANICE 

WEATHER STATION

METEOROLOGICKÁ STANICA 

METEOROLÓGIAI ÁLLOMÁS

STACJA POGODOWA

EN

CZ

SK HU

PL

SWS 280

Summary of Contents for SWS 280

Page 1: ...l Uživatelská příručka Používateľská príručka Felhasználói kézikönyv Instrukcja użytkownika METEOROLOGICKÁ STANICE WEATHER STATION METEOROLOGICKÁ STANICA METEOROLÓGIAI ÁLLOMÁS STACJA POGODOWA EN CZ SK HU PL SWS 280 ...

Page 2: ......

Page 3: ...d from Start Up Reset and the corresponded time 24 Hours Min Max Display for Outdoor Humidity 1 4 Temperature Indoor measurable range 10 50 C Measures C F user selectable Outdoor measurable range 20 50 C Outdoor Temperature Record from Start Up Reset and the corresponded time 24 Hours Min Max Display for Outdoor Temperature 1 5 Wireless Outdoor Sensor Low battery indicator for Outdoor Thermo Senso...

Page 4: ...rature Memory A5 Outdoor Humidity Memory A6 Indoor Temperature A7 Indoor Humidity A8 Time A9 Day of Week Second A10 Radio Controlled Icon A11 Alarm Icon A12 Date 2 2 Part B Buttons B1 SNOOZE LIGHT button B2 DIMMER HI LO Slide Switch B3 AL ON OFF button B4 button B5 RESET button B6 SEARCH button B7 WEATHER button B8 ALERT button B9 MEM button B10 MODE TIME SET button ...

Page 5: ... Battery Cover C3 Stand C4 DC Input 3 OUTDOOR THERMO SENSOR D1 Transmission Indication LED D2 Outdoor Temperature display D3 Outdoor Humidity display D4 Battery Compartment D5 Wall Mount Hole D6 RESET button D7 C F button D8 Stand 4 GETTING STARTED ...

Page 6: ...ace Note Transmissions between receiver and transmitter can reach up to 30m in open area Open Area there are no interfering obstacles such as buildings trees vehicles high voltage lines etc 6 WEATHER FORECAST FUNCTION 6 1 Operation After the main unit is first plugged or holding WEATHER button B7 for 3 seconds weather icon flash A1 on the LCD Enter the current weather by pressing B3 or B4 button P...

Page 7: ...stency of weather forecast between Local Weather Station and this unit the Local Weather Station s forecast should prevail The manufacture will not hold responsible for any trouble that may come up due to wrong forecasting from this unit Installation location of the outdoor sensor The cover of the external sensor is not waterproof If the sensor is located outdoors then it must be located in a cove...

Page 8: ...perature Humidity 1 Past 24 Hours Maximum Minimum Outdoor Temperature and Humidity After start up the unit automatically shows past 24 hours maximum minimum outdoor temperature and humidity record MAX MIN show on the LCD 2 Recorded Maximum Minimum Outdoor Temperature and Humidity from Start up Reset Press MEM button B9 to view the maximum and minimum temperature and humidity record from start up o...

Page 9: ...door temperature alert function press ALERT button select to Active outdoor upper temperature alert the icon besides outdoor temperature digit would display Active outdoor upper lower temperature alert the icon besides outdoor temperature digit would display Active outdoor lower temperature alert the icon besides outdoor temperature digit would display Deactivate outdoor temperature alert alert ic...

Page 10: ...minutes If receptions fail scanning stops on LCD disappear and repeats again on next full hour E g scanning failed at 8 20 a m It will scan again at 9 00 a m Stop scanning by holding and buttons B3 B4 for 3 seconds shown on the LCD if it is in Daylight Saving Time Mode 8 2 Manual Time Setting Hold MODE button B10 for 3 seconds to enter Clock Calendar setting mode Press B3 or B4 button to adjust th...

Page 11: ...n time When the country time is faster than the German time for 1 hour the zone should be set to 1 Then the clock will automatically set 1 hour faster from the signal time received 8 3 Daily Alarm Function Press MODE button B10 to select to view Time Time Day of Week Alarm Time AL shown on the LCD When viewing the Alarm Time hold MODE button B10 for 3 seconds to enter Alarm Time setting Press B3 o...

Page 12: ...y Avoid placing the clock near interference sources metal frames such as computer or TV sets The clock loses its time information when the battery is removed Do not expose it to direct sunlight heavy heat cold high humidity or wet areas The outdoor sensor must not be set up and installed under water Set it up in away direct sunlight and Rain Never clean the device using abrasive or corrosive mater...

Page 13: ...d Transmission frequency 433 MHz Transmission range up to 30 m in open space without interference Power source Weather station battery 3 x 1 5V type AA not included Power adapter DC 4 5V 150 mA included Sensor unit battery 2 x 1 5V type AAA not included Dimensions Weather station 121 x 28 x 195 mm weight 335 g Sensor 95 x 60 x 25 mm weight 65 g Fast ČR a s declares that SWS 280 SWS TH280 conform t...

Page 14: ...s and help in preventing the potential negative impact on the environment and human health which could be caused as a result of improper liquidation of waste Please ask your local authorities or the nearest waste collection centre for further details The improper disposal of this type of waste may fall subject to national regulations for fi nes For business entities in the European Union If you wi...

Page 15: ... installation This warranty is void especially if apply as follows Defects which were put on sale Wear out or damage caused by common use The product was damaged by unprofessional or wrong installation used in contrary to the applicable instruction manual used in contrary to legal enactment and common process of use or used for another purpose which has been designed for The product was damaged by...