14
Mounting Devices
•
Door/Window Contact
1.
The sensor should be on the frame while the magnet should be on the door/window.
Clean the mounting surface with a suitable degreaser agent and mount using the adhesive pads
Please note that some surfaces may be unsuitable for mounting using the adhesive pads. Please use
screwmounting in these cases.
1
3
5
6
7
2
4
a
a
b
b
max 10mm
or
(14)
(GB) Installation - (IT) Installazione - (DE) Installation - (NO) Installasjon - (SE) Installation -
(DK) Installation.
Ø 3.5mm
7
5
6
7
a
b
or
Testing
The gap between the magnet and sensor should
be no more than 10mm when closed. Test to see
whether the magnet is in range of the sensor: before
mounting hold the magnet and sensor in place and
then pull them apart. If the sensor LED lights up it
implies the two items are within range.