15
P/N AYRD-240-INST-FUL Rev E
Reset
Button
Interior Escutcheon
Factory Settings
Settings
Factory Setting
Master PIN Code
Registration
required*
Automatic Re-lock
Disabled
Inside Indicator Light
Disabled (Off)
One Touch Locking
Enabled
Volume Setting
Enabled (Low)
Automatic Re-lock Time
30 Seconds
Wrong Code Entry Limit
5 Times
Shutdown Time
60 Seconds
*The Master PIN code must be registered prior to any other
programming of the lock.
When lock is reset to factory defaults all user codes
(including the Master PIN code*) are deleted and all
programming features are reset to original default settings
(see below).
1. Remove the battery cover and batteries.
2. Remove the interior escutcheon to access the reset
button.
3. The reset button (see image at right) is located above
the PCB cable connector.
4. While pressing the reset button (minimum of 3 seconds)
reinstall batteries. Release reset button.
5. Replace battery cover.
Upon reset, Master PIN Code creation is the only option
available and must be performed prior to any other
programming of the lock.
Resetting Lock to Factory Default
Содержание Real Living YRD240
Страница 2: ...2 P N AYRD 240 INST FUL Rev E Preparing Door ...
Страница 5: ...5 P N AYRD 240 INST FUL Rev E x2 3 Installing Interior Mounting Plate Loosen screw to remove cover ...
Страница 6: ...4 Attaching the Cable Assembly 6 P N AYRD 240 INST FUL Rev E ...
Страница 7: ...7 P N AYRD 240 INST FUL Rev E x3 5 Installing Interior Escutcheon ...