background image

P/N

540WV Rev 1

YRD

7

Programming/Troubleshooting

Unit chimes to indicate code
acceptance, but door will not open.


Unit operates to allow access, but
will not automatically re-lock.

Lock does not respond –
door is locked and inaccessible.

Keypad is on for a while then shows
no reaction. Lights dim.

Apply 9V battery to terminals below the keypad for backup power option.

Batteries may be completely discharged.

Batteries do not have enough power. Replace batteries.

Check the door gaps for any foreign objects between door and frame.

Check that the cable is firmly connected to the

board.

inside lock circuit



Check to see if Auto Re-lock Mode is enabled.
Disable Auto Re-lock Mode to lock the door (automatically).
If low battery indicator is lit, change batteries.

Lock does not respond –
door is open and accessible.

Keypad becomes active when Yale logo is pressed. Verify contact with logo.

If keypad numbers are visible, check to see if they respond when pressed.

Check batteries are installed and oriented correctly (polarity) in the battery case.

Check batteries are in good condition; replace batteries if discharged.

Check to see if keypad cable is fully connected and not pinched.

Symptom

Suggested Action

Lock Jam message –

Deadbolt is taking excessive force to
retract or extend when locking or
unlocking.

Confirm door is fully closed, and there is no resistance opening or closing bolt.
Bolt should easily extend or retract when the door is closed manually.
Check door prep.



Upon entering a passcode and
pressing       key, the unit displays
" invalid code"  error or lock times out
without responding.


Lockout Mode is enabled.
Contact the Master user.

Only the Master can enable/disable Lockout Mode.

The unit operates, but it makes
no sound.

The unit responds " Low Battery"

Check to see if Silent Mode is enabled (see Feature #4).

This is the alert to replace the batteries. Replace all four (4) batteries with new

Alkaline batteries.

AA

The digits entered were incorrect or incomplete. Re-enter the correct passcode
followed by the check        key.

Upon entering a passcode and
pressing the       key, the unit
responds " Wrong  number of digits" .

Passcodes will not register.


Passcodes must consist of 4 to 8 digits to register.

The same passcode cannot be used for multiple users.

Registration/management of passcodes is set by the authority of the Master
Passcode, which is set first.

Contact the Master user.

User Passcodes must be entered within 5 seconds (while keypad is active) or
process will have to be restarted.

Back

or check

cannot be used as part of the passcode.

Содержание Nest x Yale Lock

Страница 1: ...s complete download the Nest App to add the lock to your Nest account Additional passcodes and further programming can be done in the Nest app Note that the Master Passcode may also need to be set within the app Once the Nest x Yale Lock is paired with the Nest app 20 passcodes will be available for use Refer to the following programming instructions if you are not pairing the lock with the Nest a...

Страница 2: ...e must be performed upon installation or after resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Touch the Yale logo to begin Master code is set Start by creating a Master Passcode 1 Creating Master Passcode ...

Страница 3: ...irst Max User Passcodes 20 Press Press Enter Master Passcode Press Enter 4 8 digit Passcode Press code flashes Menu options enter the number Press Press Press To end programming to finish Press Adding more User Passcodes to repeat 2 Creating User Passcodes ...

Страница 4: ...ser ___ User ___ User ___ User ___ User ___ User ___ User ___ 3 Unlocking Door with Passcodes Duplicate if necessary Passcode Chart User Name Passcode Master User Type Passcode Management Up to 20 Users User ___ User ___ User ___ User ___ P N 540WV Rev 1 YRD 4 ...

Страница 5: ...9V battery override apply 9V battery in either direction to terminals below the touchscreen for backup power option Wake up the lock and enter your passcode to unlock the door Master Passcode It must be created prior to The Master Passcode is used for programming and for feature settings programming the lock The Master Passcode will also operate unlock lock the lock One Touch Locking When the latc...

Страница 6: ...k Time 30 Seconds Wrong Passcode Entry Limit 5 Times Shutdown Time 60 Seconds The Master Passcode must be registered prior to any other programming of the lock Settings Factory Setting 1 Touch Yale logo to activate 2 Enter 4 8 digit Master Passcode followed by key Lock Response Menu options enter the number 3 Enter digit corresponding to the function to be performed followed by the key Follow the ...

Страница 7: ...t pinched Symptom Suggested Action Lock Jam message Deadbolt is taking excessive force to retract or extend when locking or unlocking Confirm door is fully closed and there is no resistance opening or closing bolt Bolt should easily extend or retract when the door is closed manually Check door prep Upon entering a passcode and pressing key the unit displays invalid code error or lock times out wit...

Страница 8: ... Using an electric driver may strip screw heads or enlarge screw holes 2 Locate strike plate tab Bend the tab towards surface of strike Note a small change may be all that is required 3 Reinstall strike plate using a manual screw driver and test again 4 If door cannot be adjusted sufficiently with strike tab both knob lever handleset latch and deadbolt latch could require adjustment we suggest you...

Страница 9: ...ble PCB connector 4 While pressing the reset button minimum of 3 seconds reinstall batteries Release reset button Lock responds with Hi from Yale and Nest 5 Replace battery cover The Master Passcode must be registered prior to any other programming of the lock NOTE TO INSTALLER AND CONSUMER While Yale has included several features to prevent lockout 9 Volt battery jumper low battery warnings it is...

Страница 10: ... vertu des règlements d Industrie Canada cet émetteur radio ne peut fonctionner avec une antenne d un type et un maximum ou moins approuvés pour gagner de l émetteur par Industrie Canada Pour réduire le risque d interférence aux autres utilisateurs le type d antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente ne PIRE dépasse pas ce qui est nécessaire p...

Отзывы: